Логотип exploitDog
Консоль
Логотип exploitDog

exploitDog

github логотип

GHSA-459j-fx99-4969

Опубликовано: 15 сент. 2022
Источник: github
Github: Не прошло ревью
CVSS3: 7.5

Описание

Improper Input Validation vulnerability in the handling of a specially crafted IEC 61850 packet with a valid data item but with incorrect data type in the IEC 61850 OPC Server in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. The vulnerability may cause a denial-of-service on the IEC 61850 OPC Server part of the SYS600 product. This issue affects: Hitachi Energy MicroSCADA Pro SYS600 version 9.4 FP2 Hotfix 4 and earlier versions Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.0:::::::* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.1:::::::* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.2:::::::* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.3:::::::* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:::::::* cpe:2.3:a:hitachienergy:microscada_x_sys600:10:::::::* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:::::::* cpe:2.3:a:hitachienergy:microscada_x_sy...

Improper Input Validation vulnerability in the handling of a specially crafted IEC 61850 packet with a valid data item but with incorrect data type in the IEC 61850 OPC Server in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. The vulnerability may cause a denial-of-service on the IEC 61850 OPC Server part of the SYS600 product. This issue affects: Hitachi Energy MicroSCADA Pro SYS600 version 9.4 FP2 Hotfix 4 and earlier versions Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.0:::::::* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.1:::::::* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.2:::::::* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.3:::::::* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:::::::* cpe:2.3:a:hitachienergy:microscada_x_sys600:10:::::::* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:::::::* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:::::::* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:::::::* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:::::::* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:::::::* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:::::::*

EPSS

Процентиль: 66%
0.0051
Низкий

7.5 High

CVSS3

Дефекты

CWE-20

Связанные уязвимости

CVSS3: 7.5
nvd
больше 3 лет назад

Improper Input Validation vulnerability in the handling of a specially crafted IEC 61850 packet with a valid data item but with incorrect data type in the IEC 61850 OPC Server in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. The vulnerability may cause a denial-of-service on the IEC 61850 OPC Server part of the SYS600 product. This issue affects: Hitachi Energy MicroSCADA Pro SYS600 version 9.4 FP2 Hotfix 4 and earlier versions Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.0:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys60

CVSS3: 7.5
fstec
почти 4 года назад

Уязвимость обработчика протокола IEC 61850 программного средства системы контроля и управления оборудованием Hitachi Energy MicroSCADA X SYS600, позволяющая нарушителю выполнить отказ в обслуживании

EPSS

Процентиль: 66%
0.0051
Низкий

7.5 High

CVSS3

Дефекты

CWE-20