GHSA-7q47-q9qw-jch6

Опубликовано: 16 июл. 2022
Источник: github
Github: Не прошло ревью
CVSS3: 6.8

Описание

Honeywell Alerton Ascent Control Module (ACM) through 2022-05-04 allows unauthenticated configuration changes from remote users. This enables configuration data to be stored on the controller and then implemented. A user with malicious intent can send a crafted packet to change the controller configuration without the knowledge of other users, altering the controller's function capabilities. The changed configuration is not updated in the User Interface, which creates an inconsistency between the configuration display and the actual configuration on the controller. After the configuration change, remediation requires reverting to the correct configuration, requiring either physical or remote access depending on the configuration that was altered.

Honeywell Alerton Ascent Control Module (ACM) through 2022-05-04 allows unauthenticated configuration changes from remote users. This enables configuration data to be stored on the controller and then implemented. A user with malicious intent can send a crafted packet to change the controller configuration without the knowledge of other users, altering the controller's function capabilities. The changed configuration is not updated in the User Interface, which creates an inconsistency between the configuration display and the actual configuration on the controller. After the configuration change, remediation requires reverting to the correct configuration, requiring either physical or remote access depending on the configuration that was altered.

EPSS

Процентиль: 30%
0.00111
Низкий

6.8 Medium

CVSS3

Связанные уязвимости

CVSS3: 6.8
nvd
больше 3 лет назад

Honeywell Alerton Ascent Control Module (ACM) through 2022-05-04 allows unauthenticated configuration changes from remote users. This enables configuration data to be stored on the controller and then implemented. A user with malicious intent can send a crafted packet to change the controller configuration without the knowledge of other users, altering the controller's function capabilities. The changed configuration is not updated in the User Interface, which creates an inconsistency between the configuration display and the actual configuration on the controller. After the configuration change, remediation requires reverting to the correct configuration, requiring either physical or remote access depending on the configuration that was altered.

EPSS

Процентиль: 30%
0.00111
Низкий

6.8 Medium

CVSS3