Описание
Sielco Sistemi Winlog Pro SCADA before 2.07.17 and Winlog Lite SCADA before 2.07.17 do not validate the return value of the realloc function, which allows remote attackers to cause a denial of service (invalid 0x00 write operation and daemon crash) or possibly have unspecified other impact via a port-46824 TCP packet with a crafted positive integer after the opcode.
Ссылки
- Exploit
- Vendor Advisory
- US Government Resource
- Exploit
- Vendor Advisory
- US Government Resource
Уязвимые конфигурации
Одно из
Одно из
EPSS
9.3 Critical
CVSS2
Дефекты
Связанные уязвимости
Sielco Sistemi Winlog Pro SCADA before 2.07.17 and Winlog Lite SCADA before 2.07.17 do not validate the return value of the realloc function, which allows remote attackers to cause a denial of service (invalid 0x00 write operation and daemon crash) or possibly have unspecified other impact via a port-46824 TCP packet with a crafted positive integer after the opcode.
EPSS
9.3 Critical
CVSS2