CVE-2017-9657

Опубликовано: 30 апр. 2018
Источник: nvd
CVSS3: 6.5
CVSS2: 3.3
EPSS Низкий

Описание

Under specific 802.11 network conditions, a partial re-association of the Philips IntelliVue MX40 Version B.06.18 WLAN monitor to the central monitoring station is possible. In this state, the central monitoring station can indicate the MX40 is not connected or associated to the central monitor, and thus should be operating in local monitoring mode (local audio-on, screen-on), but the MX40 WLAN itself can instead still be operating in telemetry mode (local audio-off, screen-off). If a patient experiences an alarm event and clinical staff expects the MX40 to provide local alarming when it is not available from the local device, a delay of treatment can occur. CVSS v3 base score: 6.5, CVSS vector string: AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H. Philips has released software update, Version B.06.18, to fix the improper cleanup on thrown exception vulnerability, and implement mitigations to reduce the risk associated with the improper handling of exceptional conditions vulnerability. The softw

Уязвимые конфигурации

Конфигурация 1

Одновременно

cpe:2.3:o:philips:intellivue_mx40_firmware:*:*:*:*:*:*:*:*
Версия до b.06.18 (исключая)
cpe:2.3:h:philips:intellivue_mx40:-:*:*:*:*:*:*:*

EPSS

Процентиль: 58%
0.0036
Низкий

6.5 Medium

CVSS3

3.3 Low

CVSS2

Дефекты

CWE-460
CWE-755

Связанные уязвимости

CVSS3: 6.5
github
больше 3 лет назад

Under specific 802.11 network conditions, a partial re-association of the Philips IntelliVue MX40 Version B.06.18 WLAN monitor to the central monitoring station is possible. In this state, the central monitoring station can indicate the MX40 is not connected or associated to the central monitor, and thus should be operating in local monitoring mode (local audio-on, screen-on), but the MX40 WLAN itself can instead still be operating in telemetry mode (local audio-off, screen-off). If a patient experiences an alarm event and clinical staff expects the MX40 to provide local alarming when it is not available from the local device, a delay of treatment can occur. CVSS v3 base score: 6.5, CVSS vector string: AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H. Philips has released software update, Version B.06.18, to fix the improper cleanup on thrown exception vulnerability, and implement mitigations to reduce the risk associated with the improper handling of exceptional conditions vulnerability. The so...

EPSS

Процентиль: 58%
0.0036
Низкий

6.5 Medium

CVSS3

3.3 Low

CVSS2

Дефекты

CWE-460
CWE-755