Логотип exploitDog
Консоль
Логотип exploitDog

exploitDog

nvd логотип

CVE-2018-16561

Опубликовано: 17 апр. 2019
Источник: nvd
CVSS3: 7.5
CVSS2: 7.8
EPSS Низкий

Описание

A vulnerability has been identified in SIMATIC S7-300 CPUs (All versions < V3.X.16). The affected CPUs improperly validate S7 communication packets which could cause a Denial-of-Service condition of the CPU. The CPU will remain in DEFECT mode until manual restart. Successful exploitation requires an attacker to be able to send a specially crafted S7 communication packet to a communication interface of the CPU. This includes Ethernet, PROFIBUS, and Multi Point Interfaces (MPI). No user interaction or privileges are required to exploit the security vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the core functionality of the CPU, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens confirms the security vulnerability and provides mitigations to resolve the security issue.

Уязвимые конфигурации

Конфигурация 1

Одновременно

cpe:2.3:o:siemens:simatic_s7-300_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_s7-300:-:*:*:*:*:*:*:*
Конфигурация 2

Одновременно

cpe:2.3:o:siemens:simatic_s7-300f_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_s7-300f:-:*:*:*:*:*:*:*
Конфигурация 3

Одновременно

cpe:2.3:o:siemens:simatic_s7-300fs_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_s7-300fs:-:*:*:*:*:*:*:*
Конфигурация 4

Одновременно

cpe:2.3:o:siemens:simatic_s7-300t_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_s7-300t:-:*:*:*:*:*:*:*

EPSS

Процентиль: 58%
0.00367
Низкий

7.5 High

CVSS3

7.8 High

CVSS2

Дефекты

NVD-CWE-noinfo

Связанные уязвимости

CVSS3: 7.5
github
больше 3 лет назад

A vulnerability has been identified in SIMATIC S7-300 CPUs (All versions < V3.X.16). The affected CPUs improperly validate S7 communication packets which could cause a Denial-of-Service condition of the CPU. The CPU will remain in DEFECT mode until manual restart. Successful exploitation requires an attacker to be able to send a specially crafted S7 communication packet to a communication interface of the CPU. This includes Ethernet, PROFIBUS, and Multi Point Interfaces (MPI). No user interaction or privileges are required to exploit the security vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the core functionality of the CPU, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens confirms the security vulnerability and provides mitigations to resolve the security issue.

CVSS3: 7.5
fstec
около 7 лет назад

Уязвимость программного обеспечения коммуникационного модуля SIMATIC S7-300 CPU Family, позволяющее нарушителю вызвать отказ в обслуживании

EPSS

Процентиль: 58%
0.00367
Низкий

7.5 High

CVSS3

7.8 High

CVSS2

Дефекты

NVD-CWE-noinfo