Логотип exploitDog
Консоль
Логотип exploitDog

exploitDog

nvd логотип

CVE-2018-3953

Опубликовано: 17 окт. 2018
Источник: nvd
CVSS3: 7.2
CVSS3: 7.2
CVSS2: 9
EPSS Средний

Описание

Devices in the Linksys ESeries line of routers (Linksys E1200 Firmware Version 2.0.09 and Linksys E2500 Firmware Version 3.0.04) are susceptible to OS command injection vulnerabilities due to improper filtering of data passed to and retrieved from NVRAM. Data entered into the 'Router Name' input field through the web portal is submitted to apply.cgi as the value to the 'machine_name' POST parameter. When the 'preinit' binary receives the SIGHUP signal, it enters a code path that continues until it reaches offset 0x0042B5C4 in the 'start_lltd' function. Within the 'start_lltd' function, a 'nvram_get' call is used to obtain the value of the user-controlled 'machine_name' NVRAM entry. This value is then entered directly into a command intended to write the host name to a file and subsequently executed.

Уязвимые конфигурации

Конфигурация 1

Одновременно

cpe:2.3:o:linksys:e1200_firmware:2.0.09:*:*:*:*:*:*:*
cpe:2.3:h:linksys:e1200:-:*:*:*:*:*:*:*
Конфигурация 2

Одновременно

cpe:2.3:o:linksys:e2500_firmware:3.0.04:*:*:*:*:*:*:*
cpe:2.3:h:linksys:e2500:-:*:*:*:*:*:*:*

EPSS

Процентиль: 99%
0.68454
Средний

7.2 High

CVSS3

7.2 High

CVSS3

9 Critical

CVSS2

Дефекты

CWE-78

Связанные уязвимости

CVSS3: 7.2
github
больше 3 лет назад

Devices in the Linksys ESeries line of routers (Linksys E1200 Firmware Version 2.0.09 and Linksys E2500 Firmware Version 3.0.04) are susceptible to OS command injection vulnerabilities due to improper filtering of data passed to and retrieved from NVRAM. Data entered into the 'Router Name' input field through the web portal is submitted to apply.cgi as the value to the 'machine_name' POST parameter. When the 'preinit' binary receives the SIGHUP signal, it enters a code path that continues until it reaches offset 0x0042B5C4 in the 'start_lltd' function. Within the 'start_lltd' function, a 'nvram_get' call is used to obtain the value of the user-controlled 'machine_name' NVRAM entry. This value is then entered directly into a command intended to write the host name to a file and subsequently executed.

CVSS3: 7.2
fstec
больше 7 лет назад

Уязвимость микропрограммного обеспечения маршрутизаторов Cisco Linksys E1200 и Cisco Linksys E2500, существующая из-за ошибок фильтрации данных, передаваемых и получаемых из NVRAM, позволяющая нарушителю выполнить произвольные команды

EPSS

Процентиль: 99%
0.68454
Средний

7.2 High

CVSS3

7.2 High

CVSS3

9 Critical

CVSS2

Дефекты

CWE-78