Логотип exploitDog
Консоль
Логотип exploitDog

exploitDog

nvd логотип

CVE-2019-5537

Опубликовано: 28 окт. 2019
Источник: nvd
CVSS3: 5.9
CVSS2: 4.3
EPSS Низкий

Описание

Sensitive information disclosure vulnerability resulting from a lack of certificate validation during the File-Based Backup and Restore operations of VMware vCenter Server Appliance (6.7 before 6.7u3a and 6.5 before 6.5u3d) may allow a malicious actor to intercept sensitive data in transit over FTPS and HTTPS. A malicious actor with man-in-the-middle positioning between vCenter Server Appliance and a backup target may be able to intercept sensitive data in transit during File-Based Backup and Restore operations.

Уязвимые конфигурации

Конфигурация 1

Одно из

cpe:2.3:a:vmware:vcenter_server:6.5:-:*:*:*:*:*:*
cpe:2.3:a:vmware:vcenter_server:6.5:a:*:*:*:*:*:*
cpe:2.3:a:vmware:vcenter_server:6.5:b:*:*:*:*:*:*
cpe:2.3:a:vmware:vcenter_server:6.5:c:*:*:*:*:*:*
cpe:2.3:a:vmware:vcenter_server:6.5:d:*:*:*:*:*:*
cpe:2.3:a:vmware:vcenter_server:6.5:e:*:*:*:*:*:*
cpe:2.3:a:vmware:vcenter_server:6.5:f:*:*:*:*:*:*
cpe:2.3:a:vmware:vcenter_server:6.5:update1:*:*:*:*:*:*
cpe:2.3:a:vmware:vcenter_server:6.5:update1b:*:*:*:*:*:*
cpe:2.3:a:vmware:vcenter_server:6.5:update1c:*:*:*:*:*:*
cpe:2.3:a:vmware:vcenter_server:6.5:update1d:*:*:*:*:*:*
cpe:2.3:a:vmware:vcenter_server:6.5:update1e:*:*:*:*:*:*
cpe:2.3:a:vmware:vcenter_server:6.5:update1g:*:*:*:*:*:*
cpe:2.3:a:vmware:vcenter_server:6.5:update2:*:*:*:*:*:*
cpe:2.3:a:vmware:vcenter_server:6.5:update2b:*:*:*:*:*:*
cpe:2.3:a:vmware:vcenter_server:6.5:update2c:*:*:*:*:*:*
cpe:2.3:a:vmware:vcenter_server:6.5:update2d:*:*:*:*:*:*
cpe:2.3:a:vmware:vcenter_server:6.5:update2g:*:*:*:*:*:*
cpe:2.3:a:vmware:vcenter_server:6.5:update3:*:*:*:*:*:*
cpe:2.3:a:vmware:vcenter_server:6.7:-:*:*:*:*:*:*
cpe:2.3:a:vmware:vcenter_server:6.7:a:*:*:*:*:*:*
cpe:2.3:a:vmware:vcenter_server:6.7:b:*:*:*:*:*:*
cpe:2.3:a:vmware:vcenter_server:6.7:d:*:*:*:*:*:*
cpe:2.3:a:vmware:vcenter_server:6.7:update1:*:*:*:*:*:*
cpe:2.3:a:vmware:vcenter_server:6.7:update1b:*:*:*:*:*:*
cpe:2.3:a:vmware:vcenter_server:6.7:update2:*:*:*:*:*:*
cpe:2.3:a:vmware:vcenter_server:6.7:update2a:*:*:*:*:*:*
cpe:2.3:a:vmware:vcenter_server:6.7:update2c:*:*:*:*:*:*
cpe:2.3:a:vmware:vcenter_server:6.7:update3:*:*:*:*:*:*

EPSS

Процентиль: 30%
0.00112
Низкий

5.9 Medium

CVSS3

4.3 Medium

CVSS2

Дефекты

CWE-295

Связанные уязвимости

github
больше 3 лет назад

Sensitive information disclosure vulnerability resulting from a lack of certificate validation during the File-Based Backup and Restore operations of VMware vCenter Server Appliance (6.7 before 6.7u3a and 6.5 before 6.5u3d) may allow a malicious actor to intercept sensitive data in transit over FTPS and HTTPS. A malicious actor with man-in-the-middle positioning between vCenter Server Appliance and a backup target may be able to intercept sensitive data in transit during File-Based Backup and Restore operations.

CVSS3: 5.9
fstec
больше 6 лет назад

Уязвимость реализации операций резервного копирования и восстановления данных программного обеспечения управления виртуальной инфраструктурой VMware vCenter Server Appliance, позволяющая нарушителю получить несанкционированный доступ к защищаемой информации

EPSS

Процентиль: 30%
0.00112
Низкий

5.9 Medium

CVSS3

4.3 Medium

CVSS2

Дефекты

CWE-295