CVE-2019-6538

Опубликовано: 25 мар. 2019
Источник: nvd
CVSS3: 9.3
CVSS3: 6.5
CVSS2: 3.3
EPSS Низкий

Описание

The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement authentication or authorization. An attacker with adjacent short-range access to an affected product, in situations where the product’s radio is turned on, can inject, replay, modify, and/or intercept data within the telemetry communication. This communication protocol provides the ability to read and write memory values to affected implanted cardiac devices; therefore, an attacker could exploit this communication protocol to change memory in the implanted cardiac device.

Ссылки

Уязвимые конфигурации

Конфигурация 1

Одновременно

Одно из

cpe:2.3:o:medtronic:mycarelink_monitor_firmware:24950:*:*:*:*:*:*:*
cpe:2.3:o:medtronic:mycarelink_monitor_firmware:24952:*:*:*:*:*:*:*
cpe:2.3:h:medtronic:mycarelink_monitor:-:*:*:*:*:*:*:*
Конфигурация 2

Одновременно

cpe:2.3:o:medtronic:carelink_monitor_firmware:2490c:*:*:*:*:*:*:*
cpe:2.3:h:medtronic:carelink_monitor:-:*:*:*:*:*:*:*
Конфигурация 3

Одновременно

cpe:2.3:o:medtronic:carelink_2090_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:medtronic:carelink_2090:-:*:*:*:*:*:*:*
Конфигурация 4

Одновременно

cpe:2.3:o:medtronic:amplia_crt-d_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:medtronic:amplia_crt-d:-:*:*:*:*:*:*:*
Конфигурация 5

Одновременно

cpe:2.3:o:medtronic:claria_crt-d_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:medtronic:claria_crt-d:-:*:*:*:*:*:*:*
Конфигурация 6

Одновременно

cpe:2.3:o:medtronic:compia_crt-d_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:medtronic:compia_crt-d:-:*:*:*:*:*:*:*
Конфигурация 7

Одновременно

cpe:2.3:o:medtronic:concerto_crt-d_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:medtronic:concerto_crt-d:-:*:*:*:*:*:*:*
Конфигурация 8

Одновременно

cpe:2.3:o:medtronic:concerto_ii_crt-d_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:medtronic:concerto_ii_crt-d:-:*:*:*:*:*:*:*
Конфигурация 9

Одновременно

cpe:2.3:o:medtronic:consulta_crt-d_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:medtronic:consulta_crt-d:-:*:*:*:*:*:*:*
Конфигурация 10

Одновременно

cpe:2.3:o:medtronic:evera_icd_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:medtronic:evera_icd:-:*:*:*:*:*:*:*
Конфигурация 11

Одновременно

cpe:2.3:o:medtronic:maximo_ii_crt-d_and_lcd_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:medtronic:maximo_ii_crt-d_and_lcd:-:*:*:*:*:*:*:*
Конфигурация 12

Одновременно

cpe:2.3:o:medtronic:mirro_icd_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:medtronic:mirro_icd:-:*:*:*:*:*:*:*
Конфигурация 13

Одновременно

cpe:2.3:o:medtronic:nayamed_nd_icd_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:medtronic:nayamed_nd_icd:-:*:*:*:*:*:*:*
Конфигурация 14

Одновременно

cpe:2.3:o:medtronic:primo_icd_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:medtronic:primo_icd:-:*:*:*:*:*:*:*
Конфигурация 15

Одновременно

cpe:2.3:o:medtronic:protecta_icd_and_crt-d_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:medtronic:protecta_icd_and_crt-d:-:*:*:*:*:*:*:*
Конфигурация 16

Одновременно

cpe:2.3:o:medtronic:secura_icd_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:medtronic:secura_icd:-:*:*:*:*:*:*:*
Конфигурация 17

Одновременно

cpe:2.3:o:medtronic:virtuoso_icd_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:medtronic:virtuoso_icd:-:*:*:*:*:*:*:*
Конфигурация 18

Одновременно

cpe:2.3:o:medtronic:virtuoso_ii_icd_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:medtronic:virtuoso_ii_icd:-:*:*:*:*:*:*:*
Конфигурация 19

Одновременно

cpe:2.3:o:medtronic:visia_af_icd_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:medtronic:visia_af_icd:-:*:*:*:*:*:*:*
Конфигурация 20

Одновременно

cpe:2.3:o:medtronic:viva_crt-d_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:medtronic:viva_crt-d:-:*:*:*:*:*:*:*

EPSS

Процентиль: 44%
0.0022
Низкий

9.3 Critical

CVSS3

6.5 Medium

CVSS3

3.3 Low

CVSS2

Дефекты

CWE-284
CWE-306

Связанные уязвимости

CVSS3: 6.5
github
больше 3 лет назад

The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement authentication or authorization. An attacker with adjacent short-range access to an affected product, in situations where the product’s radio is turned on, can inject, replay, modify, and/or intercept data within the telemetry communication. This communication protocol provides the ability to read and write memory values to affected implanted cardiac devices; therefore, an attacker could exploit this communication protocol to change memory in the implanted cardiac device.

EPSS

Процентиль: 44%
0.0022
Низкий

9.3 Critical

CVSS3

6.5 Medium

CVSS3

3.3 Low

CVSS2

Дефекты

CWE-284
CWE-306