Resource Management Errors vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products via a specially crafted packet.

Уязвимые конфигурации

Конфигурация 1

Одновременно

cpe:2.3:o:mitsubishielectric:melsec_iq-rj71eip91_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:mitsubishielectric:melsec_iq-rj71eip91:-:*:*:*:*:*:*:*
Конфигурация 2

Одновременно

cpe:2.3:o:mitsubishielectric:melsec_iq-rj71pn92_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:mitsubishielectric:melsec_iq-rj71pn92:-:*:*:*:*:*:*:*
Конфигурация 3

Одновременно

cpe:2.3:o:mitsubishielectric:melsec_iq-rd81dl96_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:mitsubishielectric:melsec_iq-rd81dl96:-:*:*:*:*:*:*:*
Конфигурация 4

Одновременно

cpe:2.3:o:mitsubishielectric:melsec_iq-rd81mes96n_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:mitsubishielectric:melsec_iq-rd81mes96n:-:*:*:*:*:*:*:*
Конфигурация 5

Одновременно

cpe:2.3:o:mitsubishielectric:melsec_iq-rd81opc96_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:mitsubishielectric:melsec_iq-rd81opc96:-:*:*:*:*:*:*:*

EPSS

Процентиль: 69%
0.006
Низкий

7.5 High

CVSS3

5 Medium

CVSS2

Дефекты

NVD-CWE-noinfo

Связанные уязвимости

github
больше 3 лет назад

Resource Management Errors vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products via a specially crafted packet.

EPSS

Процентиль: 69%
0.006
Низкий

7.5 High

CVSS3

5 Medium

CVSS2

Дефекты

NVD-CWE-noinfo