Логотип exploitDog
Консоль
Логотип exploitDog

exploitDog

nvd логотип

CVE-2021-27196

Опубликовано: 14 июн. 2021
Источник: nvd
CVSS3: 7.5
CVSS2: 5
EPSS Низкий

Описание

Improper Input Validation vulnerability in Hitachi ABB Power Grids Relion 670 Series, Relion 670/650 Series, Relion 670/650/SAM600-IO, Relion 650, REB500, RTU500 Series, FOX615 (TEGO1), MSM, GMS600, PWC600 allows an attacker with access to the IEC 61850 network with knowledge of how to reproduce the attack, as well as the IP addresses of the different IEC 61850 access points (of IEDs/products), to force the device to reboot, which renders the device inoperable for approximately 60 seconds. This vulnerability affects only products with IEC 61850 interfaces. This issue affects: Hitachi ABB Power Grids Relion 670 Series 1.1; 1.2.3 versions prior to 1.2.3.20; 2.0 versions prior to 2.0.0.13; 2.1; 2.2.2 versions prior to 2.2.2.3; 2.2.3 versions prior to 2.2.3.2. Hitachi ABB Power Grids Relion 670/650 Series 2.2.0 versions prior to 2.2.0.13. Hitachi ABB Power Grids Relion 670/650/SAM600-IO 2.2.1 versions prior to 2.2.1.6. Hitachi ABB Power Grids Relion 650 1.1; 1.2; 1.3 versions prior to 1.3.

Ссылки

Уязвимые конфигурации

Конфигурация 1

Одновременно

Одно из

cpe:2.3:o:hitachienergy:relion_670_firmware:*:*:*:*:*:*:*:*
Версия от 1.2.3 (включая) до 1.2.3.20 (исключая)
cpe:2.3:o:hitachienergy:relion_670_firmware:*:*:*:*:*:*:*:*
Версия от 2.0 (включая) до 2.0.0.13 (исключая)
cpe:2.3:o:hitachienergy:relion_670_firmware:*:*:*:*:*:*:*:*
Версия от 2.2.0 (включая) до 2.2.0.13 (исключая)
cpe:2.3:o:hitachienergy:relion_670_firmware:*:*:*:*:*:*:*:*
Версия от 2.2.1 (включая) до 2.2.1.6 (исключая)
cpe:2.3:o:hitachienergy:relion_670_firmware:*:*:*:*:*:*:*:*
Версия от 2.2.2 (включая) до 2.2.2.3 (исключая)
cpe:2.3:o:hitachienergy:relion_670_firmware:*:*:*:*:*:*:*:*
Версия от 2.2.3 (включая) до 2.2.3.2 (исключая)
cpe:2.3:o:hitachienergy:relion_670_firmware:1.1:*:*:*:*:*:*:*
cpe:2.3:o:hitachienergy:relion_670_firmware:2.1:*:*:*:*:*:*:*
cpe:2.3:h:hitachienergy:relion_670:-:*:*:*:*:*:*:*
Конфигурация 2

Одновременно

Одно из

cpe:2.3:o:hitachienergy:relion_650_firmware:*:*:*:*:*:*:*:*
Версия от 1.3 (включая) до 1.3.0.7 (исключая)
cpe:2.3:o:hitachienergy:relion_650_firmware:*:*:*:*:*:*:*:*
Версия от 2.2.0 (включая) до 2.2.0.13 (исключая)
cpe:2.3:o:hitachienergy:relion_650_firmware:*:*:*:*:*:*:*:*
Версия от 2.2.1 (включая) до 2.2.1.6 (исключая)
cpe:2.3:o:hitachienergy:relion_650_firmware:1.1:*:*:*:*:*:*:*
cpe:2.3:o:hitachienergy:relion_650_firmware:1.2:*:*:*:*:*:*:*
cpe:2.3:o:hitachienergy:relion_650_firmware:2.1:*:*:*:*:*:*:*
cpe:2.3:h:hitachienergy:relion_650:-:*:*:*:*:*:*:*
Конфигурация 3

Одновременно

cpe:2.3:o:hitachienergy:relion_sam600-io_firmware:*:*:*:*:*:*:*:*
Версия от 2.2.1 (включая) до 2.2.1.6 (исключая)
cpe:2.3:h:hitachienergy:relion_sam600-io:-:*:*:*:*:*:*:*
Конфигурация 4

Одновременно

Одно из

cpe:2.3:o:hitachienergy:rtu500_firmware:7.0:*:*:*:*:*:*:*
cpe:2.3:o:hitachienergy:rtu500_firmware:8.0:*:*:*:*:*:*:*
cpe:2.3:o:hitachienergy:rtu500_firmware:9.0:*:*:*:*:*:*:*
cpe:2.3:o:hitachienergy:rtu500_firmware:10.0:*:*:*:*:*:*:*
cpe:2.3:o:hitachienergy:rtu500_firmware:11.0:*:*:*:*:*:*:*
cpe:2.3:o:hitachienergy:rtu500_firmware:12.0:*:*:*:*:*:*:*
cpe:2.3:h:hitachienergy:rtu500:-:*:*:*:*:*:*:*
Конфигурация 5

Одновременно

Одно из

cpe:2.3:o:hitachienergy:reb500_firmware:*:*:*:*:*:*:*:*
Версия от 7.3 (включая) до 7.60.19 (исключая)
cpe:2.3:o:hitachienergy:reb500_firmware:*:*:*:*:*:*:*:*
Версия от 8.2 (включая) до 8.2.0.5 (исключая)
cpe:2.3:o:hitachienergy:reb500_firmware:*:*:*:*:*:*:*:*
Версия от 8.3 (включая) до 8.3.1.0 (включая)
cpe:2.3:h:hitachienergy:reb500:-:*:*:*:*:*:*:*
Конфигурация 6

Одновременно

cpe:2.3:o:hitachienergy:fox615_tego1_firmware:*:*:*:*:*:*:*:*
Версия до r2a16 (исключая)
cpe:2.3:h:hitachienergy:fox615_tego1:-:*:*:*:*:*:*:*
Конфигурация 7

Одновременно

cpe:2.3:o:hitachienergy:modular_switchgear_monitoring_firmware:*:*:*:*:*:*:*:*
Версия до 2.1.0 (исключая)
cpe:2.3:h:hitachienergy:modular_switchgear_monitoring:-:*:*:*:*:*:*:*
Конфигурация 8

Одновременно

cpe:2.3:o:hitachienergy:gms600_firmware:*:*:*:*:*:*:*:*
Версия до 1.3.0 (включая)
cpe:2.3:h:hitachienergy:gms600:-:*:*:*:*:*:*:*
Конфигурация 9

Одновременно

Одно из

cpe:2.3:o:hitachienergy:pwc600_firmware:*:*:*:*:*:*:*:*
Версия от 1.0 (включая) до 1.0.1.4 (исключая)
cpe:2.3:o:hitachienergy:pwc600_firmware:*:*:*:*:*:*:*:*
Версия от 1.1 (включая) до 1.1.0.1 (исключая)
cpe:2.3:h:hitachienergy:pwc600:-:*:*:*:*:*:*:*

EPSS

Процентиль: 77%
0.01045
Низкий

7.5 High

CVSS3

5 Medium

CVSS2

Дефекты

CWE-20

Связанные уязвимости

CVSS3: 7.5
github
больше 3 лет назад

Improper Input Validation vulnerability in Hitachi ABB Power Grids Relion 670 Series, Relion 670/650 Series, Relion 670/650/SAM600-IO, Relion 650, REB500, RTU500 Series, FOX615 (TEGO1), MSM, GMS600, PWC600 allows an attacker with access to the IEC 61850 network with knowledge of how to reproduce the attack, as well as the IP addresses of the different IEC 61850 access points (of IEDs/products), to force the device to reboot, which renders the device inoperable for approximately 60 seconds. This vulnerability affects only products with IEC 61850 interfaces. This issue affects: Hitachi ABB Power Grids Relion 670 Series 1.1; 1.2.3 versions prior to 1.2.3.20; 2.0 versions prior to 2.0.0.13; 2.1; 2.2.2 versions prior to 2.2.2.3; 2.2.3 versions prior to 2.2.3.2. Hitachi ABB Power Grids Relion 670/650 Series 2.2.0 versions prior to 2.2.0.13. Hitachi ABB Power Grids Relion 670/650/SAM600-IO 2.2.1 versions prior to 2.2.1.6. Hitachi ABB Power Grids Relion 650 1.1; 1.2; 1.3 versions prior to 1...

EPSS

Процентиль: 77%
0.01045
Низкий

7.5 High

CVSS3

5 Medium

CVSS2

Дефекты

CWE-20