Логотип exploitDog
Консоль
Логотип exploitDog

exploitDog

nvd логотип

CVE-2021-31890

Опубликовано: 09 нояб. 2021
Источник: nvd
CVSS3: 7.5
CVSS3: 9.1
CVSS2: 6.4
EPSS Низкий

Описание

A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions < V1.0.0.0). The total length of an TCP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on the network buffer organization in memory. (FSMD-2021-0017)

Уязвимые конфигурации

Конфигурация 1

Одно из

cpe:2.3:a:siemens:capital_vstar:*:*:*:*:*:*:*:*
cpe:2.3:a:siemens:nucleus_net:*:*:*:*:*:*:*:*
cpe:2.3:a:siemens:nucleus_readystart_v3:*:*:*:*:*:*:*:*
Версия до 2017.02.4 (исключая)
cpe:2.3:a:siemens:nucleus_readystart_v4:*:*:*:*:*:*:*:*
Версия до 4.1.1 (исключая)
cpe:2.3:a:siemens:nucleus_source_code:*:*:*:*:*:*:*:*
Конфигурация 2

Одновременно

cpe:2.3:o:siemens:apogee_modular_building_controller_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:apogee_modular_building_controller:-:*:*:*:*:*:*:*
Конфигурация 3

Одновременно

cpe:2.3:o:siemens:apogee_modular_equiment_controller_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:apogee_modular_equiment_controller:-:*:*:*:*:*:*:*
Конфигурация 4

Одновременно

cpe:2.3:o:siemens:apogee_pxc_compact_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:apogee_pxc_compact:-:*:*:*:*:*:*:*
Конфигурация 5

Одновременно

cpe:2.3:o:siemens:apogee_pxc_modular_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:apogee_pxc_modular:-:*:*:*:*:*:*:*
Конфигурация 6

Одновременно

cpe:2.3:o:siemens:talon_tc_compact_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:talon_tc_compact:-:*:*:*:*:*:*:*
Конфигурация 7

Одновременно

cpe:2.3:o:siemens:talon_tc_modular_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:talon_tc_modular:-:*:*:*:*:*:*:*

EPSS

Процентиль: 85%
0.02496
Низкий

7.5 High

CVSS3

9.1 Critical

CVSS3

6.4 Medium

CVSS2

Дефекты

CWE-240

Связанные уязвимости

CVSS3: 9.1
github
больше 3 лет назад

A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions), APOGEE PXC Compact (P2 Ethernet) (All versions), APOGEE PXC Modular (BACnet) (All versions), APOGEE PXC Modular (P2 Ethernet) (All versions), Capital VSTAR (All versions), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.1), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions), TALON TC Modular (BACnet) (All versions). The total length of an TCP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on the network buffer organization in memory. (FSMD-2021-0017)

CVSS3: 9.1
fstec
около 4 лет назад

Уязвимость микропрограммного обеспечения контроллеров CAPITAL VSTAR, APOGEE MBC, APOGEE MEC, APOGEE PXC, TALON TC и операционной системы Nucleus, связанная с ошибками при обработке заголовка TCP-пакета, позволяющая нарушителю получить доступ к защищаемой информации или вызвать отказ в обслуживании

EPSS

Процентиль: 85%
0.02496
Низкий

7.5 High

CVSS3

9.1 Critical

CVSS3

6.4 Medium

CVSS2

Дефекты

CWE-240