Описание
The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-306: Missing Authentication for Critical Function, which allows unauthorized users to change the operator account password via webserver commands by monitoring web socket communications from an unauthenticated session. This could allow an attacker to escalate privileges to match those of the compromised account.
Ссылки
- Third Party AdvisoryUS Government Resource
- Third Party AdvisoryUS Government Resource
Уязвимые конфигурации
Одновременно
EPSS
9.8 Critical
CVSS3
Дефекты
Связанные уязвимости
The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-306: Missing Authentication for Critical Function, which allows unauthorized users to change the operator account password via webserver commands by monitoring web socket communications from an unauthenticated session. This could allow an attacker to escalate privileges to match those of the compromised account.
Уязвимость микропрограммного обеспечения cистемы объемного измерения Cognex 3D-A1000 Dimensioning System, связанная с отсутствием проверки подлинности для функции изменения пароля, позволяющая нарушителю повысить свои привилегии