In the Linux kernel, the following vulnerability has been resolved:

drm/msm/dp: populate connector of struct dp_panel

DP CTS test case 4.2.2.6 has valid edid with bad checksum on purpose and expect DP source return correct checksum. During drm edid read, correct edid checksum is calculated and stored at connector::real_edid_checksum.

The problem is struct dp_panel::connector never be assigned, instead the connector is stored in struct msm_dp::connector. When we run compliance testing test case 4.2.2.6 dp_panel_handle_sink_request() won't have a valid edid set in struct dp_panel::edid so we'll try to use the connectors real_edid_checksum and hit a NULL pointer dereference error because the connector pointer is never assigned.

Changes in V2: -- populate panel connector at msm_dp_modeset_init() instead of at dp_panel_read_sink_caps()

Changes in V3: -- remove unhelpful kernel crash trace commit text -- remove renaming dp_display parameter to dp

Changes in V4: -- add more details to c

Уязвимые конфигурации

Конфигурация 1

Одно из

cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*
Версия от 5.10.67 (включая) до 5.10.110 (исключая)
cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*
Версия от 5.13.19 (включая) до 5.14 (исключая)
cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*
Версия от 5.14.6 (включая) до 5.15.33 (исключая)
cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*
Версия от 5.16 (включая) до 5.16.19 (исключая)
cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*
Версия от 5.17 (включая) до 5.17.2 (исключая)

EPSS

Процентиль: 10%
0.00035
Низкий

5.5 Medium

CVSS3

Дефекты

CWE-476
CWE-476

Связанные уязвимости

CVSS3: 5.5
ubuntu
12 месяцев назад

In the Linux kernel, the following vulnerability has been resolved: drm/msm/dp: populate connector of struct dp_panel DP CTS test case 4.2.2.6 has valid edid with bad checksum on purpose and expect DP source return correct checksum. During drm edid read, correct edid checksum is calculated and stored at connector::real_edid_checksum. The problem is struct dp_panel::connector never be assigned, instead the connector is stored in struct msm_dp::connector. When we run compliance testing test case 4.2.2.6 dp_panel_handle_sink_request() won't have a valid edid set in struct dp_panel::edid so we'll try to use the connectors real_edid_checksum and hit a NULL pointer dereference error because the connector pointer is never assigned. Changes in V2: -- populate panel connector at msm_dp_modeset_init() instead of at dp_panel_read_sink_caps() Changes in V3: -- remove unhelpful kernel crash trace commit text -- remove renaming dp_display parameter to dp Changes in V4: -- add more details to comm...

CVSS3: 5.5
redhat
12 месяцев назад

In the Linux kernel, the following vulnerability has been resolved: drm/msm/dp: populate connector of struct dp_panel DP CTS test case 4.2.2.6 has valid edid with bad checksum on purpose and expect DP source return correct checksum. During drm edid read, correct edid checksum is calculated and stored at connector::real_edid_checksum. The problem is struct dp_panel::connector never be assigned, instead the connector is stored in struct msm_dp::connector. When we run compliance testing test case 4.2.2.6 dp_panel_handle_sink_request() won't have a valid edid set in struct dp_panel::edid so we'll try to use the connectors real_edid_checksum and hit a NULL pointer dereference error because the connector pointer is never assigned. Changes in V2: -- populate panel connector at msm_dp_modeset_init() instead of at dp_panel_read_sink_caps() Changes in V3: -- remove unhelpful kernel crash trace commit text -- remove renaming dp_display parameter to dp Changes in V4: -- add more details to comm...

CVSS3: 5.5
debian
12 месяцев назад

In the Linux kernel, the following vulnerability has been resolved: d ...

CVSS3: 5.5
github
11 месяцев назад

In the Linux kernel, the following vulnerability has been resolved: drm/msm/dp: populate connector of struct dp_panel DP CTS test case 4.2.2.6 has valid edid with bad checksum on purpose and expect DP source return correct checksum. During drm edid read, correct edid checksum is calculated and stored at connector::real_edid_checksum. The problem is struct dp_panel::connector never be assigned, instead the connector is stored in struct msm_dp::connector. When we run compliance testing test case 4.2.2.6 dp_panel_handle_sink_request() won't have a valid edid set in struct dp_panel::edid so we'll try to use the connectors real_edid_checksum and hit a NULL pointer dereference error because the connector pointer is never assigned. Changes in V2: -- populate panel connector at msm_dp_modeset_init() instead of at dp_panel_read_sink_caps() Changes in V3: -- remove unhelpful kernel crash trace commit text -- remove renaming dp_display parameter to dp Changes in V4: -- add more details t...

suse-cvrf
11 месяцев назад

Security update for the Linux Kernel

EPSS

Процентиль: 10%
0.00035
Низкий

5.5 Medium

CVSS3

Дефекты

CWE-476
CWE-476