CVE-2023-22611

Опубликовано: 31 янв. 2023
Источник: nvd
CVSS3: 7.5
EPSS Низкий

Описание

A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause information disclosure when specific messages are sent to the server over the database server TCP port. Affected Products: EcoStruxure Geo SCADA Expert 2019 - 2021 (formerly known as ClearSCADA) (Versions prior to October 2022)

Уязвимые конфигурации

Конфигурация 1

Одно из

cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:-:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7268.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7322.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7429.2:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7457.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7488.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7522.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7545.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7578.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7613.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7641.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7690.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7714.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7742.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7777.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7808.2:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7840.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7875.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7896.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7936.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7980.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.8015.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.8108.2:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.8122.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.8155.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.8172.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.8197.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.8220.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.8267.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:-:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7551.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7578.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7613.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7641.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7692.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7717.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7742.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7787.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7809.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7840.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7875.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7913.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7936.2:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7980.2:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.8017.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.8108.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.8122.2:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.8155.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.8181.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.8197.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.8221.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.8267.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2021:-:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2021:84.8027.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2021:84.8108.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2021:84.8120.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2021:84.8158.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2021:84.8182.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2021:84.8197.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2021:84.8218.1:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2021:84.8269.1:*:*:*:*:*:*:*

EPSS

Процентиль: 62%
0.00424
Низкий

7.5 High

CVSS3

Дефекты

CWE-200
NVD-CWE-noinfo

Связанные уязвимости

CVSS3: 7.5
github
больше 2 лет назад

A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause information disclosure when specific messages are sent to the server over the database server TCP port. Affected Products: EcoStruxure™ Geo SCADA Expert 2019, EcoStruxure™ Geo SCADA Expert 2020, EcoStruxure™ Geo SCADA Expert 2021 (All versions prior to October 2022), ClearSCADA (All Versions).

CVSS3: 4.3
fstec
около 3 лет назад

Уязвимость SCADA-систем EcoStruxure Geo SCADA Expert 2020, EcoStruxure Geo SCADA Expert 2019, связанная с отсутствием защиты служебных данных, позволяющая нарушителю раскрыть защищаемую информацию

EPSS

Процентиль: 62%
0.00424
Низкий

7.5 High

CVSS3

Дефекты

CWE-200
NVD-CWE-noinfo