Логотип exploitDog
Консоль
Логотип exploitDog

exploitDog

nvd логотип

CVE-2026-68182

Опубликовано: 10 авг. 2026
Источник: nvd
EPSS Низкий

Описание

In the Linux kernel, the following vulnerability has been resolved:

comedi: comedi_parport: deal with premature interrupt

Syzbot reported a general protection fault in comedi_get_is_subdevice_running(), which was called from the interrupt handler parport_interrupt() in the "comedi_parport" driver, but it does not currently have a C reproducer for the problem. It's probably due to a premature interrupt for one of two reasons:

  1. The driver sets up the interrupt handler before the comedi subdevices used by the interrupt handler have been allocated, but does not disable the interrupt in the parallel port's CTRL register first.
  2. The driver uses a user-supplied I/O port base address which Syzbot would have supplied, but it might not be backed by real parallel port hardware.

Change the initialization order in the driver's comedi "attach" handler (parport_attach()) so that the hardware registers are initialized before the interrupt handler is requested. This should p

EPSS

Процентиль: 11%
0.0021
Низкий

Дефекты

Связанные уязвимости

ubuntu
22 дня назад

In the Linux kernel, the following vulnerability has been resolved: comedi: comedi_parport: deal with premature interrupt Syzbot reported a general protection fault in `comedi_get_is_subdevice_running()`, which was called from the interrupt handler `parport_interrupt()` in the "comedi_parport" driver, but it does not currently have a C reproducer for the problem. It's probably due to a premature interrupt for one of two reasons: 1. The driver sets up the interrupt handler before the comedi subdevices used by the interrupt handler have been allocated, but does not disable the interrupt in the parallel port's CTRL register first. 2. The driver uses a user-supplied I/O port base address which Syzbot would have supplied, but it might not be backed by real parallel port hardware. Change the initialization order in the driver's comedi "attach" handler (`parport_attach()`) so that the hardware registers are initialized before the interrupt handler is requested. This should prevent premat...

CVSS3: 5.5
redhat
22 дня назад

In the Linux kernel, the following vulnerability has been resolved: comedi: comedi_parport: deal with premature interrupt Syzbot reported a general protection fault in `comedi_get_is_subdevice_running()`, which was called from the interrupt handler `parport_interrupt()` in the "comedi_parport" driver, but it does not currently have a C reproducer for the problem. It's probably due to a premature interrupt for one of two reasons: 1. The driver sets up the interrupt handler before the comedi subdevices used by the interrupt handler have been allocated, but does not disable the interrupt in the parallel port's CTRL register first. 2. The driver uses a user-supplied I/O port base address which Syzbot would have supplied, but it might not be backed by real parallel port hardware. Change the initialization order in the driver's comedi "attach" handler (`parport_attach()`) so that the hardware registers are initialized before the interrupt handler is requested. This should prevent premat...

CVSS3: 7.1
msrc
21 день назад

comedi: comedi_parport: deal with premature interrupt

debian
22 дня назад

In the Linux kernel, the following vulnerability has been resolved: c ...

github
22 дня назад

In the Linux kernel, the following vulnerability has been resolved: comedi: comedi_parport: deal with premature interrupt Syzbot reported a general protection fault in `comedi_get_is_subdevice_running()`, which was called from the interrupt handler `parport_interrupt()` in the "comedi_parport" driver, but it does not currently have a C reproducer for the problem. It's probably due to a premature interrupt for one of two reasons: 1. The driver sets up the interrupt handler before the comedi subdevices used by the interrupt handler have been allocated, but does not disable the interrupt in the parallel port's CTRL register first. 2. The driver uses a user-supplied I/O port base address which Syzbot would have supplied, but it might not be backed by real parallel port hardware. Change the initialization order in the driver's comedi "attach" handler (`parport_attach()`) so that the hardware registers are initialized before the interrupt handler is requested. This shoul...

EPSS

Процентиль: 11%
0.0021
Низкий

Дефекты