Описание

Security update for xen

This update for xen fixes the following issues:

  • CVE-2022-26356: Fixed potential race conditions in dirty memory tracking that could cause a denial of service in the host (bsc#1197423).
  • CVE-2022-26357: Fixed a potential race condition in memory cleanup for hosts using VT-d IOMMU hardware, which could lead to a denial of service in the host (bsc#1197425).
  • CVE-2022-26358,CVE-2022-26359,CVE-2022-26360,CVE-2022-26361: Fixed various memory corruption issues for hosts using VT-d or AMD-Vi IOMMU hardware. These could be leveraged by an attacker to cause a denial of service in the host (bsc#1197426).
  • CVE-2022-0001, CVE-2022-0002, CVE-2021-26401: Added BHB speculation issue mitigations (bsc#1196915).

Список пакетов

SUSE Linux Enterprise Server 12 SP4-LTSS
xen-4.11.4_28-2.73.1
xen-doc-html-4.11.4_28-2.73.1
xen-libs-4.11.4_28-2.73.1
xen-libs-32bit-4.11.4_28-2.73.1
xen-tools-4.11.4_28-2.73.1
xen-tools-domU-4.11.4_28-2.73.1
SUSE Linux Enterprise Server for SAP Applications 12 SP4
xen-4.11.4_28-2.73.1
xen-doc-html-4.11.4_28-2.73.1
xen-libs-4.11.4_28-2.73.1
xen-libs-32bit-4.11.4_28-2.73.1
xen-tools-4.11.4_28-2.73.1
xen-tools-domU-4.11.4_28-2.73.1
SUSE OpenStack Cloud 9
xen-4.11.4_28-2.73.1
xen-doc-html-4.11.4_28-2.73.1
xen-libs-4.11.4_28-2.73.1
xen-libs-32bit-4.11.4_28-2.73.1
xen-tools-4.11.4_28-2.73.1
xen-tools-domU-4.11.4_28-2.73.1
SUSE OpenStack Cloud Crowbar 9
xen-4.11.4_28-2.73.1
xen-doc-html-4.11.4_28-2.73.1
xen-libs-4.11.4_28-2.73.1
xen-libs-32bit-4.11.4_28-2.73.1
xen-tools-4.11.4_28-2.73.1
xen-tools-domU-4.11.4_28-2.73.1

Описание

LFENCE/JMP (mitigation V2-2) may not sufficiently mitigate CVE-2017-5715 on some AMD CPUs.


Затронутые продукты
SUSE Linux Enterprise Server 12 SP4-LTSS:xen-4.11.4_28-2.73.1
SUSE Linux Enterprise Server 12 SP4-LTSS:xen-doc-html-4.11.4_28-2.73.1
SUSE Linux Enterprise Server 12 SP4-LTSS:xen-libs-32bit-4.11.4_28-2.73.1
SUSE Linux Enterprise Server 12 SP4-LTSS:xen-libs-4.11.4_28-2.73.1

Ссылки

Описание

Non-transparent sharing of branch predictor selectors between contexts in some Intel(R) Processors may allow an authorized user to potentially enable information disclosure via local access.


Затронутые продукты
SUSE Linux Enterprise Server 12 SP4-LTSS:xen-4.11.4_28-2.73.1
SUSE Linux Enterprise Server 12 SP4-LTSS:xen-doc-html-4.11.4_28-2.73.1
SUSE Linux Enterprise Server 12 SP4-LTSS:xen-libs-32bit-4.11.4_28-2.73.1
SUSE Linux Enterprise Server 12 SP4-LTSS:xen-libs-4.11.4_28-2.73.1

Ссылки

Описание

Non-transparent sharing of branch predictor within a context in some Intel(R) Processors may allow an authorized user to potentially enable information disclosure via local access.


Затронутые продукты
SUSE Linux Enterprise Server 12 SP4-LTSS:xen-4.11.4_28-2.73.1
SUSE Linux Enterprise Server 12 SP4-LTSS:xen-doc-html-4.11.4_28-2.73.1
SUSE Linux Enterprise Server 12 SP4-LTSS:xen-libs-32bit-4.11.4_28-2.73.1
SUSE Linux Enterprise Server 12 SP4-LTSS:xen-libs-4.11.4_28-2.73.1

Ссылки

Описание

Racy interactions between dirty vram tracking and paging log dirty hypercalls Activation of log dirty mode done by XEN_DMOP_track_dirty_vram (was named HVMOP_track_dirty_vram before Xen 4.9) is racy with ongoing log dirty hypercalls. A suitably timed call to XEN_DMOP_track_dirty_vram can enable log dirty while another CPU is still in the process of tearing down the structures related to a previously enabled log dirty mode (XEN_DOMCTL_SHADOW_OP_OFF). This is due to lack of mutually exclusive locking between both operations and can lead to entries being added in already freed slots, resulting in a memory leak.


Затронутые продукты
SUSE Linux Enterprise Server 12 SP4-LTSS:xen-4.11.4_28-2.73.1
SUSE Linux Enterprise Server 12 SP4-LTSS:xen-doc-html-4.11.4_28-2.73.1
SUSE Linux Enterprise Server 12 SP4-LTSS:xen-libs-32bit-4.11.4_28-2.73.1
SUSE Linux Enterprise Server 12 SP4-LTSS:xen-libs-4.11.4_28-2.73.1

Ссылки

Описание

race in VT-d domain ID cleanup Xen domain IDs are up to 15 bits wide. VT-d hardware may allow for only less than 15 bits to hold a domain ID associating a physical device with a particular domain. Therefore internally Xen domain IDs are mapped to the smaller value range. The cleaning up of the housekeeping structures has a race, allowing for VT-d domain IDs to be leaked and flushes to be bypassed.


Затронутые продукты
SUSE Linux Enterprise Server 12 SP4-LTSS:xen-4.11.4_28-2.73.1
SUSE Linux Enterprise Server 12 SP4-LTSS:xen-doc-html-4.11.4_28-2.73.1
SUSE Linux Enterprise Server 12 SP4-LTSS:xen-libs-32bit-4.11.4_28-2.73.1
SUSE Linux Enterprise Server 12 SP4-LTSS:xen-libs-4.11.4_28-2.73.1

Ссылки

Описание

IOMMU: RMRR (VT-d) and unity map (AMD-Vi) handling issues T[his CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] Certain PCI devices in a system might be assigned Reserved Memory Regions (specified via Reserved Memory Region Reporting, "RMRR") for Intel VT-d or Unity Mapping ranges for AMD-Vi. These are typically used for platform tasks such as legacy USB emulation. Since the precise purpose of these regions is unknown, once a device associated with such a region is active, the mappings of these regions need to remain continuouly accessible by the device. This requirement has been violated. Subsequent DMA or interrupts from the device may have unpredictable behaviour, ranging from IOMMU faults to memory corruption.


Затронутые продукты
SUSE Linux Enterprise Server 12 SP4-LTSS:xen-4.11.4_28-2.73.1
SUSE Linux Enterprise Server 12 SP4-LTSS:xen-doc-html-4.11.4_28-2.73.1
SUSE Linux Enterprise Server 12 SP4-LTSS:xen-libs-32bit-4.11.4_28-2.73.1
SUSE Linux Enterprise Server 12 SP4-LTSS:xen-libs-4.11.4_28-2.73.1

Ссылки

Описание

IOMMU: RMRR (VT-d) and unity map (AMD-Vi) handling issues T[his CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] Certain PCI devices in a system might be assigned Reserved Memory Regions (specified via Reserved Memory Region Reporting, "RMRR") for Intel VT-d or Unity Mapping ranges for AMD-Vi. These are typically used for platform tasks such as legacy USB emulation. Since the precise purpose of these regions is unknown, once a device associated with such a region is active, the mappings of these regions need to remain continuouly accessible by the device. This requirement has been violated. Subsequent DMA or interrupts from the device may have unpredictable behaviour, ranging from IOMMU faults to memory corruption.


Затронутые продукты
SUSE Linux Enterprise Server 12 SP4-LTSS:xen-4.11.4_28-2.73.1
SUSE Linux Enterprise Server 12 SP4-LTSS:xen-doc-html-4.11.4_28-2.73.1
SUSE Linux Enterprise Server 12 SP4-LTSS:xen-libs-32bit-4.11.4_28-2.73.1
SUSE Linux Enterprise Server 12 SP4-LTSS:xen-libs-4.11.4_28-2.73.1

Ссылки

Описание

IOMMU: RMRR (VT-d) and unity map (AMD-Vi) handling issues T[his CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] Certain PCI devices in a system might be assigned Reserved Memory Regions (specified via Reserved Memory Region Reporting, "RMRR") for Intel VT-d or Unity Mapping ranges for AMD-Vi. These are typically used for platform tasks such as legacy USB emulation. Since the precise purpose of these regions is unknown, once a device associated with such a region is active, the mappings of these regions need to remain continuouly accessible by the device. This requirement has been violated. Subsequent DMA or interrupts from the device may have unpredictable behaviour, ranging from IOMMU faults to memory corruption.


Затронутые продукты
SUSE Linux Enterprise Server 12 SP4-LTSS:xen-4.11.4_28-2.73.1
SUSE Linux Enterprise Server 12 SP4-LTSS:xen-doc-html-4.11.4_28-2.73.1
SUSE Linux Enterprise Server 12 SP4-LTSS:xen-libs-32bit-4.11.4_28-2.73.1
SUSE Linux Enterprise Server 12 SP4-LTSS:xen-libs-4.11.4_28-2.73.1

Ссылки

Описание

IOMMU: RMRR (VT-d) and unity map (AMD-Vi) handling issues T[his CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] Certain PCI devices in a system might be assigned Reserved Memory Regions (specified via Reserved Memory Region Reporting, "RMRR") for Intel VT-d or Unity Mapping ranges for AMD-Vi. These are typically used for platform tasks such as legacy USB emulation. Since the precise purpose of these regions is unknown, once a device associated with such a region is active, the mappings of these regions need to remain continuouly accessible by the device. This requirement has been violated. Subsequent DMA or interrupts from the device may have unpredictable behaviour, ranging from IOMMU faults to memory corruption.


Затронутые продукты
SUSE Linux Enterprise Server 12 SP4-LTSS:xen-4.11.4_28-2.73.1
SUSE Linux Enterprise Server 12 SP4-LTSS:xen-doc-html-4.11.4_28-2.73.1
SUSE Linux Enterprise Server 12 SP4-LTSS:xen-libs-32bit-4.11.4_28-2.73.1
SUSE Linux Enterprise Server 12 SP4-LTSS:xen-libs-4.11.4_28-2.73.1

Ссылки
Уязвимость SUSE-SU-2022:1285-1