Количество 3
Количество 3
CVE-2013-2796
Schneider Electric Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier allow remote attackers to read arbitrary files, send HTTP requests to intranet servers, or cause a denial of service (CPU and memory consumption) via an XML document containing an external entity declaration in conjunction with an entity reference, related to an XML External Entity (XXE) issue.
GHSA-fxqp-5cfq-qj7q
Schneider Electric Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier allow remote attackers to read arbitrary files, send HTTP requests to intranet servers, or cause a denial of service (CPU and memory consumption) via an XML document containing an external entity declaration in conjunction with an entity reference, related to an XML External Entity (XXE) issue.
BDU:2019-03752
Уязвимость систем для сбора данных и контроля процессов промышленной автоматизации Vijeo Citect, CitectSCADA и PowerLogic SCADA, связанная с недостатками разграничения доступа к некоторым функциям, позволяющая нарушителю читать произвольные файлы, отправлять HTTP-запросы или вызвать отказ в обслуживании
Уязвимостей на страницу
Уязвимость | CVSS | EPSS | Опубликовано | |
|---|---|---|---|---|
CVE-2013-2796 Schneider Electric Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier allow remote attackers to read arbitrary files, send HTTP requests to intranet servers, or cause a denial of service (CPU and memory consumption) via an XML document containing an external entity declaration in conjunction with an entity reference, related to an XML External Entity (XXE) issue. | CVSS2: 6.9 | 0% Низкий | больше 12 лет назад | |
GHSA-fxqp-5cfq-qj7q Schneider Electric Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier allow remote attackers to read arbitrary files, send HTTP requests to intranet servers, or cause a denial of service (CPU and memory consumption) via an XML document containing an external entity declaration in conjunction with an entity reference, related to an XML External Entity (XXE) issue. | 0% Низкий | больше 3 лет назад | ||
BDU:2019-03752 Уязвимость систем для сбора данных и контроля процессов промышленной автоматизации Vijeo Citect, CitectSCADA и PowerLogic SCADA, связанная с недостатками разграничения доступа к некоторым функциям, позволяющая нарушителю читать произвольные файлы, отправлять HTTP-запросы или вызвать отказ в обслуживании | CVSS3: 8.4 | больше 6 лет назад |