Количество 2
Количество 2
CVE-2018-2858
Vulnerability in the Sun ZFS Storage Appliance Kit (AK) component of Oracle Sun Systems Products Suite (subcomponent: HTTP data path subsystems). The supported version that is affected is Prior to 8.7.17. Easily exploitable vulnerability allows unauthenticated attacker with network access via HTTP to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks of this vulnerability can result in unauthorized read access to a subset of Sun ZFS Storage Appliance Kit (AK) accessible data. CVSS 3.0 Base Score 5.3 (Confidentiality impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N).
GHSA-c7cf-wh8q-pxxh
Vulnerability in the Sun ZFS Storage Appliance Kit (AK) component of Oracle Sun Systems Products Suite (subcomponent: HTTP data path subsystems). The supported version that is affected is Prior to 8.7.17. Easily exploitable vulnerability allows unauthenticated attacker with network access via HTTP to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks of this vulnerability can result in unauthorized read access to a subset of Sun ZFS Storage Appliance Kit (AK) accessible data. CVSS 3.0 Base Score 5.3 (Confidentiality impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N).
Уязвимостей на страницу
Уязвимость | CVSS | EPSS | Опубликовано | |
|---|---|---|---|---|
CVE-2018-2858 Vulnerability in the Sun ZFS Storage Appliance Kit (AK) component of Oracle Sun Systems Products Suite (subcomponent: HTTP data path subsystems). The supported version that is affected is Prior to 8.7.17. Easily exploitable vulnerability allows unauthenticated attacker with network access via HTTP to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks of this vulnerability can result in unauthorized read access to a subset of Sun ZFS Storage Appliance Kit (AK) accessible data. CVSS 3.0 Base Score 5.3 (Confidentiality impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N). | CVSS3: 5.3 | 1% Низкий | почти 8 лет назад | |
GHSA-c7cf-wh8q-pxxh Vulnerability in the Sun ZFS Storage Appliance Kit (AK) component of Oracle Sun Systems Products Suite (subcomponent: HTTP data path subsystems). The supported version that is affected is Prior to 8.7.17. Easily exploitable vulnerability allows unauthenticated attacker with network access via HTTP to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks of this vulnerability can result in unauthorized read access to a subset of Sun ZFS Storage Appliance Kit (AK) accessible data. CVSS 3.0 Base Score 5.3 (Confidentiality impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N). | CVSS3: 5.3 | 1% Низкий | больше 3 лет назад |
Уязвимостей на страницу