Логотип exploitDog
bind:CVE-2022-28005
Консоль
Логотип exploitDog

exploitDog

bind:CVE-2022-28005

Количество 2

Количество 2

nvd логотип

CVE-2022-28005

почти 4 года назад

An issue was discovered in the 3CX Phone System Management Console prior to version 18 Update 3 FINAL. An unauthenticated attacker could abuse improperly secured access to arbitrary files on the server (via /Electron/download directory traversal in conjunction with a path component that uses backslash characters), leading to cleartext credential disclosure. Afterwards, the authenticated attacker is able to upload a file that overwrites a 3CX service binary, leading to Remote Code Execution as NT AUTHORITY\SYSTEM on Windows installations. NOTE: this issue exists because of an incomplete fix for CVE-2022-48482.

CVSS3: 9.8
EPSS: Средний
github логотип

GHSA-m9wh-p6h4-rmvw

почти 4 года назад

An issue was discovered in the 3CX Phone System Management Console prior to version 18 Update 3 FINAL. An unauthenticated attacker could abuse improperly secured access to arbitrary files on the server, leading to cleartext credential disclosure. Afterwards, the authenticated attacker is able to upload a file that overwrites a 3CX service binary, leading to Remote Code Execution as NT AUTHORITY\SYSTEM on Windows installations. Versions prior to version 18, Hotfix 1 Build 18.0.3.461 March 2022, are prone to an additional unauthenticated file system access to C:\Windows\System32.

CVSS3: 9.8
EPSS: Средний

Уязвимостей на страницу

Уязвимость
CVSS
EPSS
Опубликовано
nvd логотип
CVE-2022-28005

An issue was discovered in the 3CX Phone System Management Console prior to version 18 Update 3 FINAL. An unauthenticated attacker could abuse improperly secured access to arbitrary files on the server (via /Electron/download directory traversal in conjunction with a path component that uses backslash characters), leading to cleartext credential disclosure. Afterwards, the authenticated attacker is able to upload a file that overwrites a 3CX service binary, leading to Remote Code Execution as NT AUTHORITY\SYSTEM on Windows installations. NOTE: this issue exists because of an incomplete fix for CVE-2022-48482.

CVSS3: 9.8
21%
Средний
почти 4 года назад
github логотип
GHSA-m9wh-p6h4-rmvw

An issue was discovered in the 3CX Phone System Management Console prior to version 18 Update 3 FINAL. An unauthenticated attacker could abuse improperly secured access to arbitrary files on the server, leading to cleartext credential disclosure. Afterwards, the authenticated attacker is able to upload a file that overwrites a 3CX service binary, leading to Remote Code Execution as NT AUTHORITY\SYSTEM on Windows installations. Versions prior to version 18, Hotfix 1 Build 18.0.3.461 March 2022, are prone to an additional unauthenticated file system access to C:\Windows\System32.

CVSS3: 9.8
21%
Средний
почти 4 года назад

Уязвимостей на страницу