Логотип exploitDog
bind:CVE-2022-4608
Консоль
Логотип exploitDog

exploitDog

bind:CVE-2022-4608

Количество 3

Количество 3

nvd логотип

CVE-2022-4608

больше 2 лет назад

A vulnerability exists in HCI IEC 60870-5-104 function included in certain versions of the RTU500 series product. The vulnerability can only be exploited, if the HCI 60870-5-104 is configured with support for IEC 62351-3. After session resumption interval is expired an RTU500 initiated update of session parameters causes an unexpected restart due to a stack overflow.

CVSS3: 7.5
EPSS: Низкий
github логотип

GHSA-5568-g9wp-2cv7

больше 2 лет назад

A vulnerability exists in HCI IEC 60870-5-104 function included in certain versions of the RTU500 series product. The vulnerability can only be exploited, if the HCI 60870-5-104 is configured with support for IEC 62351-3. After session resumption interval is expired an RTU500 initiated update of session parameters causes an unexpected restart due to a stack overflow.

CVSS3: 7.5
EPSS: Низкий
fstec логотип

BDU:2023-04551

больше 2 лет назад

Уязвимость интерфейса HCI (Host Controller Interface), функционирующего по стандарту IEC 60870-5-104, программируемых логических контроллеров Hitachi Energy RTU500, позволяющая нарушителю вызвать отказ в обслуживании

CVSS3: 7.5
EPSS: Низкий

Уязвимостей на страницу

Уязвимость
CVSS
EPSS
Опубликовано
nvd логотип
CVE-2022-4608

A vulnerability exists in HCI IEC 60870-5-104 function included in certain versions of the RTU500 series product. The vulnerability can only be exploited, if the HCI 60870-5-104 is configured with support for IEC 62351-3. After session resumption interval is expired an RTU500 initiated update of session parameters causes an unexpected restart due to a stack overflow.

CVSS3: 7.5
0%
Низкий
больше 2 лет назад
github логотип
GHSA-5568-g9wp-2cv7

A vulnerability exists in HCI IEC 60870-5-104 function included in certain versions of the RTU500 series product. The vulnerability can only be exploited, if the HCI 60870-5-104 is configured with support for IEC 62351-3. After session resumption interval is expired an RTU500 initiated update of session parameters causes an unexpected restart due to a stack overflow.

CVSS3: 7.5
0%
Низкий
больше 2 лет назад
fstec логотип
BDU:2023-04551

Уязвимость интерфейса HCI (Host Controller Interface), функционирующего по стандарту IEC 60870-5-104, программируемых логических контроллеров Hitachi Energy RTU500, позволяющая нарушителю вызвать отказ в обслуживании

CVSS3: 7.5
0%
Низкий
больше 2 лет назад

Уязвимостей на страницу