Количество 3
Количество 3
CVE-2024-1574
Use of Externally-Controlled Input to Select Classes or Code ('Unsafe Reflection') vulnerability in the licensing feature of Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.2, Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.2, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.2, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.2, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions BizViz versions 9.7 and prior, Mitsubishi Electric BizViz versions 9.7 and prior, and Mitsubishi Electric MC Works64 all versions allows a local attacker to execute a malicious code with administrative privileges by tampering with a specific file that is not protected by the system.
GHSA-m7g5-qwgm-89mc
Use of Externally-Controlled Input to Select Classes or Code ('Unsafe Reflection') vulnerability in the licensing feature of ICONICS GENESIS64 versions 10.97 to 10.97.2, Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.2 and Mitsubishi Electric MC Works64 all versions allows a local attacker to execute a malicious code with administrative privileges by tampering with a specific file that is not protected by the system.
BDU:2024-10624
Уязвимость SCADA-системы GENESIS64 программных пакетов для диспетчерского управления и сбора данных MC Works64, связанная с применением входных данных с внешним управлением для выбора классов, позволяющая нарушителю выполнить произвольный код
Уязвимостей на страницу
Уязвимость | CVSS | EPSS | Опубликовано | |
|---|---|---|---|---|
CVE-2024-1574 Use of Externally-Controlled Input to Select Classes or Code ('Unsafe Reflection') vulnerability in the licensing feature of Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.2, Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.2, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.2, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.2, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions BizViz versions 9.7 and prior, Mitsubishi Electric BizViz versions 9.7 and prior, and Mitsubishi Electric MC Works64 all versions allows a local attacker to execute a malicious code with administrative privileges by tampering with a specific file that is not protected by the system. | CVSS3: 6.7 | 0% Низкий | больше 1 года назад | |
GHSA-m7g5-qwgm-89mc Use of Externally-Controlled Input to Select Classes or Code ('Unsafe Reflection') vulnerability in the licensing feature of ICONICS GENESIS64 versions 10.97 to 10.97.2, Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.2 and Mitsubishi Electric MC Works64 all versions allows a local attacker to execute a malicious code with administrative privileges by tampering with a specific file that is not protected by the system. | CVSS3: 6.7 | 0% Низкий | больше 1 года назад | |
BDU:2024-10624 Уязвимость SCADA-системы GENESIS64 программных пакетов для диспетчерского управления и сбора данных MC Works64, связанная с применением входных данных с внешним управлением для выбора классов, позволяющая нарушителю выполнить произвольный код | CVSS3: 6.7 | 0% Низкий | больше 1 года назад |
Уязвимостей на страницу