CVE-2025-66051
Vivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal. It is possible for an authenticated attacker to access resources beyond webroot directory using a direct HTTP request. Due to CVE-2025-66050, a password for administration panel is not set by default. The vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.
GHSA-22q2-ww3p-hj7f
Vivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal. It is possible for an authenticated attacker to access resources beyond webroot directory using a direct HTTP request. Due to CVE-2025-66050, a password for administration panel is not set by default. The vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.
BDU:2026-00868
Уязвимость микропрограммного обеспечения IP-камер Vivotek IP7137, связанная с неверным ограничением имени пути к каталогу с ограниченным доступом, позволяющая нарушителю получить несанкционированный доступ к защищаемой информации
Уязвимостей на страницу
Уязвимость | CVSS | EPSS | Опубликовано | |
|---|---|---|---|---|
CVE-2025-66051 Vivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal. It is possible for an authenticated attacker to access resources beyond webroot directory using a direct HTTP request. Due to CVE-2025-66050, a password for administration panel is not set by default. The vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released. | CVSS3: 6.5 | 0% Низкий | 3 месяца назад | |
GHSA-22q2-ww3p-hj7f Vivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal. It is possible for an authenticated attacker to access resources beyond webroot directory using a direct HTTP request. Due to CVE-2025-66050, a password for administration panel is not set by default. The vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released. | CVSS3: 6.5 | 0% Низкий | 3 месяца назад | |
BDU:2026-00868 Уязвимость микропрограммного обеспечения IP-камер Vivotek IP7137, связанная с неверным ограничением имени пути к каталогу с ограниченным доступом, позволяющая нарушителю получить несанкционированный доступ к защищаемой информации | CVSS3: 4.9 | 0% Низкий | 3 месяца назад |
Уязвимостей на страницу