Количество 3
Количество 3
CVE-2026-25857
Tenda G300-F router firmware version 16.01.14.2 and prior contain an OS command injection vulnerability in the WAN diagnostic functionality (formSetWanDiag). The implementation constructs a shell command that invokes curl and incorporates attacker-controlled input into the command line without adequate neutralization. As a result, a remote attacker with access to the affected management interface can inject additional shell syntax and execute arbitrary commands on the device with the privileges of the management process.
GHSA-m35g-p77j-hqrh
Tenda G300-F router firmware versio 16.01.14.2 and prior contain an OS command injection vulnerability in the WAN diagnostic functionality (formSetWanDiag). The implementation constructs a shell command that invokes curl and incorporates attacker-controlled input into the command line without adequate neutralization. As a result, a remote attacker with access to the affected management interface can inject additional shell syntax and execute arbitrary commands on the device with the privileges of the management process.
BDU:2026-01506
Уязвимость функции formSetWanDiag() микропрограммного обеспечения маршрутизаторов Tenda G300-F, позволяющая нарушителю выполнить произвольный код
Уязвимостей на страницу
Уязвимость | CVSS | EPSS | Опубликовано | |
|---|---|---|---|---|
CVE-2026-25857 Tenda G300-F router firmware version 16.01.14.2 and prior contain an OS command injection vulnerability in the WAN diagnostic functionality (formSetWanDiag). The implementation constructs a shell command that invokes curl and incorporates attacker-controlled input into the command line without adequate neutralization. As a result, a remote attacker with access to the affected management interface can inject additional shell syntax and execute arbitrary commands on the device with the privileges of the management process. | CVSS3: 8.8 | 3% Низкий | 6 месяцев назад | |
GHSA-m35g-p77j-hqrh Tenda G300-F router firmware versio 16.01.14.2 and prior contain an OS command injection vulnerability in the WAN diagnostic functionality (formSetWanDiag). The implementation constructs a shell command that invokes curl and incorporates attacker-controlled input into the command line without adequate neutralization. As a result, a remote attacker with access to the affected management interface can inject additional shell syntax and execute arbitrary commands on the device with the privileges of the management process. | CVSS3: 8.8 | 3% Низкий | 6 месяцев назад | |
BDU:2026-01506 Уязвимость функции formSetWanDiag() микропрограммного обеспечения маршрутизаторов Tenda G300-F, позволяющая нарушителю выполнить произвольный код | CVSS3: 7.2 | 3% Низкий | 6 месяцев назад |
Уязвимостей на страницу