CVE-2012-3037
The Siemens SIMATIC S7-1200 2.x PLC does not properly protect the private key of the SIMATIC CONTROLLER Certification Authority certificate, which allows remote attackers to spoof the S7-1200 web server by using this key to create a forged certificate.
CVE-2012-3036
Rejected reason: DO NOT USE THIS CANDIDATE NUMBER. ConsultIDs: none. Reason: This candidate was in a CNA pool that was not assigned to any issues during 2012. Notes: none
CVE-2012-3035
Buffer overflow in Emerson DeltaV 9.3.1 and 10.3 through 11.3.1 allows remote attackers to cause a denial of service (daemon crash) via a long string to an unspecified port.
CVE-2012-3034
WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to discover a username and password via crafted parameters to unspecified methods in ActiveX controls.
CVE-2012-3033
Rejected reason: DO NOT USE THIS CANDIDATE NUMBER. ConsultIDs: none. Reason: This candidate was in a CNA pool that was not assigned to any issues during 2012. Notes: none
CVE-2012-3032
SQL injection vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to execute arbitrary SQL commands via a crafted SOAP message.
CVE-2012-3031
Multiple cross-site scripting (XSS) vulnerabilities in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allow remote attackers to inject arbitrary web script or HTML via a (1) GET parameter, (2) POST parameter, or (3) Referer HTTP header.
CVE-2012-3030
WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, stores sensitive information under the web root with insufficient access control, which allows remote attackers to read a (1) log file or (2) configuration file via a direct request.
CVE-2012-3029
Rejected reason: DO NOT USE THIS CANDIDATE NUMBER. ConsultIDs: none. Reason: This candidate was in a CNA pool that was not assigned to any issues during 2012. Notes: none
CVE-2012-3028
Cross-site request forgery (CSRF) vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to hijack the authentication of arbitrary users for requests that modify data or cause a denial of service.
CVE-2012-3027
Rejected reason: DO NOT USE THIS CANDIDATE NUMBER. ConsultIDs: none. Reason: This candidate was in a CNA pool that was not assigned to any issues during 2012. Notes: none
CVE-2012-3026
rifsrvd.exe in the Remote Interface Service in GE Intelligent Platforms Proficy Real-Time Information Portal 2.6 through 3.5 SP1 allows remote attackers to cause a denial of service (memory corruption and service crash) or possibly execute arbitrary code via long input data, a different vulnerability than CVE-2012-3010 and CVE-2012-3021.
CVE-2012-3025
The default configuration of Tridium Niagara AX Framework through 3.6 uses a cleartext base64 format for transmission of credentials in cookies, which allows remote attackers to obtain sensitive information by sniffing the network.
CVE-2012-3024
Tridium Niagara AX Framework through 3.6 uses predictable values for (1) session IDs and (2) keys, which might allow remote attackers to bypass authentication via a brute-force attack.
CVE-2012-3022
The SaveToFile method in a certain ActiveX control in TrendDisplay.dll in Canary Labs TrendLink 9.0.2.27051 and earlier does not properly restrict the creation of files, which allows remote attackers to download an arbitrary program onto a client machine, and execute this program, via a crafted web site.
CVE-2012-3021
rifsrvd.exe in the Remote Interface Service in GE Intelligent Platforms Proficy Real-Time Information Portal 2.6 through 3.5 SP1 allows remote attackers to cause a denial of service (memory corruption and service crash) or possibly execute arbitrary code via long input data, a different vulnerability than CVE-2012-3010 and CVE-2012-3026.
CVE-2012-3020
The Siemens Synco OZW Web Server devices OZW672.*, OZW772.*, and OZW775 with firmware before 4 have an unspecified default password, which makes it easier for remote attackers to obtain administrative access via a network session.
CVE-2012-3018
The lockout-recovery feature in the Security Configurator component in ICONICS GENESIS32 9.22 and earlier and BizViz 9.22 and earlier uses an improper encryption algorithm for generation of an authentication code, which allows local users to bypass intended access restrictions and obtain administrative access by predicting a challenge response.
CVE-2012-3017
Siemens SIMATIC S7-400 PN CPU devices with firmware 5.x allow remote attackers to cause a denial of service (defect-mode transition and service outage) via (1) malformed HTTP traffic or (2) malformed IP packets.
CVE-2012-3016
Siemens SIMATIC S7-400 PN CPU devices with firmware 6 before 6.0.3 allow remote attackers to cause a denial of service (defect-mode transition and service outage) via crafted ICMP packets.
Уязвимостей на страницу
Уязвимость | CVSS | EPSS | Опубликовано | |
|---|---|---|---|---|
CVE-2012-3037 The Siemens SIMATIC S7-1200 2.x PLC does not properly protect the private key of the SIMATIC CONTROLLER Certification Authority certificate, which allows remote attackers to spoof the S7-1200 web server by using this key to create a forged certificate. | CVSS2: 4.3 | 1% Низкий | почти 14 лет назад | |
CVE-2012-3036 Rejected reason: DO NOT USE THIS CANDIDATE NUMBER. ConsultIDs: none. Reason: This candidate was in a CNA pool that was not assigned to any issues during 2012. Notes: none | больше 9 лет назад | |||
CVE-2012-3035 Buffer overflow in Emerson DeltaV 9.3.1 and 10.3 through 11.3.1 allows remote attackers to cause a denial of service (daemon crash) via a long string to an unspecified port. | CVSS2: 5 | 2% Низкий | почти 14 лет назад | |
CVE-2012-3034 WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to discover a username and password via crafted parameters to unspecified methods in ActiveX controls. | CVSS2: 4.3 | 2% Низкий | около 14 лет назад | |
CVE-2012-3033 Rejected reason: DO NOT USE THIS CANDIDATE NUMBER. ConsultIDs: none. Reason: This candidate was in a CNA pool that was not assigned to any issues during 2012. Notes: none | больше 9 лет назад | |||
CVE-2012-3032 SQL injection vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to execute arbitrary SQL commands via a crafted SOAP message. | CVSS2: 7.5 | 2% Низкий | около 14 лет назад | |
CVE-2012-3031 Multiple cross-site scripting (XSS) vulnerabilities in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allow remote attackers to inject arbitrary web script or HTML via a (1) GET parameter, (2) POST parameter, or (3) Referer HTTP header. | CVSS2: 4.3 | 2% Низкий | около 14 лет назад | |
CVE-2012-3030 WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, stores sensitive information under the web root with insufficient access control, which allows remote attackers to read a (1) log file or (2) configuration file via a direct request. | CVSS2: 5 | 3% Низкий | около 14 лет назад | |
CVE-2012-3029 Rejected reason: DO NOT USE THIS CANDIDATE NUMBER. ConsultIDs: none. Reason: This candidate was in a CNA pool that was not assigned to any issues during 2012. Notes: none | больше 9 лет назад | |||
CVE-2012-3028 Cross-site request forgery (CSRF) vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to hijack the authentication of arbitrary users for requests that modify data or cause a denial of service. | CVSS2: 6.8 | 1% Низкий | около 14 лет назад | |
CVE-2012-3027 Rejected reason: DO NOT USE THIS CANDIDATE NUMBER. ConsultIDs: none. Reason: This candidate was in a CNA pool that was not assigned to any issues during 2012. Notes: none | больше 9 лет назад | |||
CVE-2012-3026 rifsrvd.exe in the Remote Interface Service in GE Intelligent Platforms Proficy Real-Time Information Portal 2.6 through 3.5 SP1 allows remote attackers to cause a denial of service (memory corruption and service crash) or possibly execute arbitrary code via long input data, a different vulnerability than CVE-2012-3010 and CVE-2012-3021. | CVSS2: 10 | 5% Низкий | почти 14 лет назад | |
CVE-2012-3025 The default configuration of Tridium Niagara AX Framework through 3.6 uses a cleartext base64 format for transmission of credentials in cookies, which allows remote attackers to obtain sensitive information by sniffing the network. | CVSS2: 5 | 2% Низкий | около 14 лет назад | |
CVE-2012-3024 Tridium Niagara AX Framework through 3.6 uses predictable values for (1) session IDs and (2) keys, which might allow remote attackers to bypass authentication via a brute-force attack. | CVSS2: 5 | 2% Низкий | около 14 лет назад | |
CVE-2012-3022 The SaveToFile method in a certain ActiveX control in TrendDisplay.dll in Canary Labs TrendLink 9.0.2.27051 and earlier does not properly restrict the creation of files, which allows remote attackers to download an arbitrary program onto a client machine, and execute this program, via a crafted web site. | CVSS2: 8.5 | 1% Низкий | больше 13 лет назад | |
CVE-2012-3021 rifsrvd.exe in the Remote Interface Service in GE Intelligent Platforms Proficy Real-Time Information Portal 2.6 through 3.5 SP1 allows remote attackers to cause a denial of service (memory corruption and service crash) or possibly execute arbitrary code via long input data, a different vulnerability than CVE-2012-3010 and CVE-2012-3026. | CVSS2: 10 | 5% Низкий | почти 14 лет назад | |
CVE-2012-3020 The Siemens Synco OZW Web Server devices OZW672.*, OZW772.*, and OZW775 with firmware before 4 have an unspecified default password, which makes it easier for remote attackers to obtain administrative access via a network session. | CVSS2: 7.5 | 1% Низкий | около 14 лет назад | |
CVE-2012-3018 The lockout-recovery feature in the Security Configurator component in ICONICS GENESIS32 9.22 and earlier and BizViz 9.22 and earlier uses an improper encryption algorithm for generation of an authentication code, which allows local users to bypass intended access restrictions and obtain administrative access by predicting a challenge response. | CVSS2: 4.4 | 0% Низкий | около 14 лет назад | |
CVE-2012-3017 Siemens SIMATIC S7-400 PN CPU devices with firmware 5.x allow remote attackers to cause a denial of service (defect-mode transition and service outage) via (1) malformed HTTP traffic or (2) malformed IP packets. | CVSS2: 7.8 | 3% Низкий | около 14 лет назад | |
CVE-2012-3016 Siemens SIMATIC S7-400 PN CPU devices with firmware 6 before 6.0.3 allow remote attackers to cause a denial of service (defect-mode transition and service outage) via crafted ICMP packets. | CVSS2: 7.8 | 3% Низкий | около 14 лет назад |