Количество 2
Количество 2
CVE-2017-16304
Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd sn_ex, at 0x9d01ae40, the value for the `d` key is copied using `strcpy` to the buffer at `$sp+0x334`.This buffer is 100 bytes large, sending anything longer will cause a buffer overflow.
GHSA-mjcv-779p-53wp
Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd sn_ex, at 0x9d01ae40, the value for the `d` key is copied using `strcpy` to the buffer at `$sp+0x334`.This buffer is 100 bytes large, sending anything longer will cause a buffer overflow.
Уязвимостей на страницу
Уязвимость | CVSS | EPSS | Опубликовано | |
|---|---|---|---|---|
CVE-2017-16304 Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd sn_ex, at 0x9d01ae40, the value for the `d` key is copied using `strcpy` to the buffer at `$sp+0x334`.This buffer is 100 bytes large, sending anything longer will cause a buffer overflow. | CVSS3: 9.9 | 0% Низкий | около 3 лет назад | |
GHSA-mjcv-779p-53wp Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd sn_ex, at 0x9d01ae40, the value for the `d` key is copied using `strcpy` to the buffer at `$sp+0x334`.This buffer is 100 bytes large, sending anything longer will cause a buffer overflow. | CVSS3: 9.9 | 0% Низкий | около 3 лет назад |
Уязвимостей на страницу