CVE-2020-12028
In all versions of FactoryTalk View SEA remote, an authenticated attacker may be able to utilize certain handlers to interact with the data on the remote endpoint since those handlers do not enforce appropriate permissions. Rockwell Automation recommends enabling built in security features found within FactoryTalk View SE. Users should follow guidance found in knowledge base articles 109056 and 1126943 to set up IPSec and/or HTTPs.
GHSA-524h-35w7-86xp
In all versions of FactoryTalk View SEA remote, an authenticated attacker may be able to utilize certain handlers to interact with the data on the remote endpoint since those handlers do not enforce appropriate permissions. Rockwell Automation recommends enabling built in security features found within FactoryTalk View SE. Users should follow guidance found in knowledge base articles 109056 and 1126943 to set up IPSec and/or HTTPs.
BDU:2025-07165
Уязвимость программного средства управления человеко-машинными интерфейсами (HMI) Rockwell Automation FactoryTalk View SE, связанная с отсутствием аутентификации для критичной функции, позволяющая нарушителю обойти ограничения безопасности и записывать произвольные файлы
Уязвимостей на страницу
Уязвимость | CVSS | EPSS | Опубликовано | |
|---|---|---|---|---|
CVE-2020-12028 In all versions of FactoryTalk View SEA remote, an authenticated attacker may be able to utilize certain handlers to interact with the data on the remote endpoint since those handlers do not enforce appropriate permissions. Rockwell Automation recommends enabling built in security features found within FactoryTalk View SE. Users should follow guidance found in knowledge base articles 109056 and 1126943 to set up IPSec and/or HTTPs. | CVSS3: 7.3 | 30% Средний | больше 5 лет назад | |
GHSA-524h-35w7-86xp In all versions of FactoryTalk View SEA remote, an authenticated attacker may be able to utilize certain handlers to interact with the data on the remote endpoint since those handlers do not enforce appropriate permissions. Rockwell Automation recommends enabling built in security features found within FactoryTalk View SE. Users should follow guidance found in knowledge base articles 109056 and 1126943 to set up IPSec and/or HTTPs. | CVSS3: 8.1 | 30% Средний | больше 3 лет назад | |
BDU:2025-07165 Уязвимость программного средства управления человеко-машинными интерфейсами (HMI) Rockwell Automation FactoryTalk View SE, связанная с отсутствием аутентификации для критичной функции, позволяющая нарушителю обойти ограничения безопасности и записывать произвольные файлы | CVSS3: 7.3 | 30% Средний | около 6 лет назад |
Уязвимостей на страницу