Количество 3
Количество 3
CVE-2021-0264
A vulnerability in the processing of traffic matching a firewall filter containing a syslog action in Juniper Networks Junos OS on MX Series with MPC10/MPC11 cards installed, PTX10003 and PTX10008 Series devices, will cause the line card to crash and restart, creating a Denial of Service (DoS). Continued receipt and processing of packets matching the firewall filter can create a sustained Denial of Service (DoS) condition. When traffic hits the firewall filter, configured on lo0 or any physical interface on the line card, containing a term with a syslog action (e.g. 'term <name> then syslog'), the affected line card will crash and restart, impacting traffic processing through the ports of the line card. This issue only affects MX Series routers with MPC10 or MPC11 line cards, and PTX10003 or PTX10008 Series packet transport routers. No other platforms or models of line cards are affected by this issue. Note: This issue has also been identified and described in technical service bulleti
GHSA-x88h-4vmv-82q6
A vulnerability in the processing of traffic matching a firewall filter containing a syslog action in Juniper Networks Junos OS on MX Series with MPC10/MPC11 cards installed, PTX10003 and PTX10008 Series devices, will cause the line card to crash and restart, creating a Denial of Service (DoS). Continued receipt and processing of packets matching the firewall filter can create a sustained Denial of Service (DoS) condition. When traffic hits the firewall filter, configured on lo0 or any physical interface on the line card, containing a term with a syslog action (e.g. 'term <name> then syslog'), the affected line card will crash and restart, impacting traffic processing through the ports of the line card. This issue only affects MX Series routers with MPC10 or MPC11 line cards, and PTX10003 or PTX10008 Series packet transport routers. No other platforms or models of line cards are affected by this issue. Note: This issue has also been identified and described in technical service bull...
BDU:2021-03227
Уязвимость конфигурации фильтров брандмауэра операционных систем Junos OS маршрутизаторов серии MX, PTX10003 и PTX10008, позволяющая нарушителю вызвать отказ в обслуживании
Уязвимостей на страницу
Уязвимость | CVSS | EPSS | Опубликовано | |
|---|---|---|---|---|
CVE-2021-0264 A vulnerability in the processing of traffic matching a firewall filter containing a syslog action in Juniper Networks Junos OS on MX Series with MPC10/MPC11 cards installed, PTX10003 and PTX10008 Series devices, will cause the line card to crash and restart, creating a Denial of Service (DoS). Continued receipt and processing of packets matching the firewall filter can create a sustained Denial of Service (DoS) condition. When traffic hits the firewall filter, configured on lo0 or any physical interface on the line card, containing a term with a syslog action (e.g. 'term <name> then syslog'), the affected line card will crash and restart, impacting traffic processing through the ports of the line card. This issue only affects MX Series routers with MPC10 or MPC11 line cards, and PTX10003 or PTX10008 Series packet transport routers. No other platforms or models of line cards are affected by this issue. Note: This issue has also been identified and described in technical service bulleti | CVSS3: 5.9 | 0% Низкий | почти 5 лет назад | |
GHSA-x88h-4vmv-82q6 A vulnerability in the processing of traffic matching a firewall filter containing a syslog action in Juniper Networks Junos OS on MX Series with MPC10/MPC11 cards installed, PTX10003 and PTX10008 Series devices, will cause the line card to crash and restart, creating a Denial of Service (DoS). Continued receipt and processing of packets matching the firewall filter can create a sustained Denial of Service (DoS) condition. When traffic hits the firewall filter, configured on lo0 or any physical interface on the line card, containing a term with a syslog action (e.g. 'term <name> then syslog'), the affected line card will crash and restart, impacting traffic processing through the ports of the line card. This issue only affects MX Series routers with MPC10 or MPC11 line cards, and PTX10003 or PTX10008 Series packet transport routers. No other platforms or models of line cards are affected by this issue. Note: This issue has also been identified and described in technical service bull... | 0% Низкий | больше 3 лет назад | ||
BDU:2021-03227 Уязвимость конфигурации фильтров брандмауэра операционных систем Junos OS маршрутизаторов серии MX, PTX10003 и PTX10008, позволяющая нарушителю вызвать отказ в обслуживании | CVSS3: 5.9 | 0% Низкий | почти 5 лет назад |
Уязвимостей на страницу