Логотип exploitDog
bind:CVE-2021-31342
Консоль
Логотип exploitDog

exploitDog

bind:CVE-2021-31342

Количество 3

Количество 3

nvd логотип

CVE-2021-31342

больше 4 лет назад

The ugeom2d.dll library in all versions of Solid Edge SE2020 before 2020MP14 and all versions of Solid Edge SE2021 before SE2021MP5 lack proper validation of user-supplied data when parsing DFT files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.

CVSS3: 8.8
EPSS: Низкий
github логотип

GHSA-xphh-j59m-3cvp

больше 3 лет назад

A vulnerability has been identified in Solid Edge SE2020 (All Versions < 2020MP14), Solid Edge SE2021 (All Versions < SE2021MP5). The ugeom2d.dll library lacks proper validation of user-supplied data when parsing DFT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12993)

EPSS: Низкий
fstec логотип

BDU:2021-03581

больше 4 лет назад

Уязвимость динамически подключаемой библиотеки ugeom2d.dll набора инструментов для проектирования и моделирования Siemens Solid Edge, позволяющая нарушителю выполнить произвольный код

CVSS3: 7.8
EPSS: Низкий

Уязвимостей на страницу

Уязвимость
CVSS
EPSS
Опубликовано
nvd логотип
CVE-2021-31342

The ugeom2d.dll library in all versions of Solid Edge SE2020 before 2020MP14 and all versions of Solid Edge SE2021 before SE2021MP5 lack proper validation of user-supplied data when parsing DFT files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.

CVSS3: 8.8
1%
Низкий
больше 4 лет назад
github логотип
GHSA-xphh-j59m-3cvp

A vulnerability has been identified in Solid Edge SE2020 (All Versions < 2020MP14), Solid Edge SE2021 (All Versions < SE2021MP5). The ugeom2d.dll library lacks proper validation of user-supplied data when parsing DFT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12993)

1%
Низкий
больше 3 лет назад
fstec логотип
BDU:2021-03581

Уязвимость динамически подключаемой библиотеки ugeom2d.dll набора инструментов для проектирования и моделирования Siemens Solid Edge, позволяющая нарушителю выполнить произвольный код

CVSS3: 7.8
1%
Низкий
больше 4 лет назад

Уязвимостей на страницу