Логотип exploitDog
bind:CVE-2023-31174
Консоль
Логотип exploitDog

exploitDog

bind:CVE-2023-31174

Количество 3

Количество 3

nvd логотип

CVE-2023-31174

больше 2 лет назад

A Cross-Site Request Forgery (CSRF) vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to embed instructions that could be executed by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.

CVSS3: 7.4
EPSS: Низкий
github логотип

GHSA-g3hq-7qpp-8rv2

больше 2 лет назад

A Cross-Site Request Forgery (CSRF) vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to embed instructions that could be executed by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.

CVSS3: 7.4
EPSS: Низкий
fstec логотип

BDU:2023-05820

больше 2 лет назад

Уязвимость программного конфигуратора для создания, управления и развертывания энергосистем SEL-5037 SEL Grid Configurator, связанная с недостаточной проверкой подлинности выполняемых запросов, позволяющая нарушителю осуществить CSRF-атаку

CVSS3: 7.4
EPSS: Низкий

Уязвимостей на страницу

Уязвимость
CVSS
EPSS
Опубликовано
nvd логотип
CVE-2023-31174

A Cross-Site Request Forgery (CSRF) vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to embed instructions that could be executed by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.

CVSS3: 7.4
0%
Низкий
больше 2 лет назад
github логотип
GHSA-g3hq-7qpp-8rv2

A Cross-Site Request Forgery (CSRF) vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to embed instructions that could be executed by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.

CVSS3: 7.4
0%
Низкий
больше 2 лет назад
fstec логотип
BDU:2023-05820

Уязвимость программного конфигуратора для создания, управления и развертывания энергосистем SEL-5037 SEL Grid Configurator, связанная с недостаточной проверкой подлинности выполняемых запросов, позволяющая нарушителю осуществить CSRF-атаку

CVSS3: 7.4
0%
Низкий
больше 2 лет назад

Уязвимостей на страницу