Количество 3
Количество 3
CVE-2023-31222
Deserialization of untrusted data in Microsoft Messaging Queuing Service in Medtronic's Paceart Optima versions 1.11 and earlier on Windows allows an unauthorized user to impact a healthcare delivery organization’s Paceart Optima system cardiac device causing data to be deleted, stolen, or modified, or the Paceart Optima system being used for further network penetration via network connectivity.
GHSA-g4h4-ww84-r75w
Deserialization of untrusted data in Microsoft Messaging Queuing Service in Medtronic's Paceart Optima versions 1.11 and earlier on Windows allows an unauthorized user to impact a healthcare delivery organization’s Paceart Optima system cardiac device causing data to be deleted, stolen, or modified, or the Paceart Optima system being used for further network penetration via network connectivity.
BDU:2023-03556
Уязвимость службы Paceart Messaging Service системы мониторинга кардиологических устройств Paceart Optima, позволяющая нарушителю получить несанкционированный доступ на чтение, изменение или удаление данных, выполнить произвольный код или вызвать отказ в обслуживании
Уязвимостей на страницу
Уязвимость | CVSS | EPSS | Опубликовано | |
|---|---|---|---|---|
CVE-2023-31222 Deserialization of untrusted data in Microsoft Messaging Queuing Service in Medtronic's Paceart Optima versions 1.11 and earlier on Windows allows an unauthorized user to impact a healthcare delivery organization’s Paceart Optima system cardiac device causing data to be deleted, stolen, or modified, or the Paceart Optima system being used for further network penetration via network connectivity. | CVSS3: 9.8 | 29% Средний | больше 2 лет назад | |
GHSA-g4h4-ww84-r75w Deserialization of untrusted data in Microsoft Messaging Queuing Service in Medtronic's Paceart Optima versions 1.11 and earlier on Windows allows an unauthorized user to impact a healthcare delivery organization’s Paceart Optima system cardiac device causing data to be deleted, stolen, or modified, or the Paceart Optima system being used for further network penetration via network connectivity. | CVSS3: 9.8 | 29% Средний | больше 2 лет назад | |
BDU:2023-03556 Уязвимость службы Paceart Messaging Service системы мониторинга кардиологических устройств Paceart Optima, позволяющая нарушителю получить несанкционированный доступ на чтение, изменение или удаление данных, выполнить произвольный код или вызвать отказ в обслуживании | CVSS3: 9.8 | 29% Средний | почти 3 года назад |
Уязвимостей на страницу