Логотип exploitDog
bind:CVE-2023-35796
Консоль
Логотип exploitDog

exploitDog

bind:CVE-2023-35796

Количество 3

Количество 3

nvd логотип

CVE-2023-35796

больше 2 лет назад

A vulnerability has been identified in SINEMA Server V14 (All versions). The affected application improperly sanitizes certain SNMP configuration data retrieved from monitored devices. An attacker with access to a monitored device could perform a stored cross-site scripting (XSS) attack that may lead to arbitrary code execution with `SYSTEM` privileges on the application server. (ZDI-CAN-19823)

CVSS3: 8.3
EPSS: Низкий
github логотип

GHSA-8w38-353q-pxjf

больше 2 лет назад

A vulnerability has been identified in SINEMA Server V14 (All versions). The affected application improperly sanitizes certain SNMP configuration data retrieved from monitored devices. An attacker with access to a monitored device could perform a stored cross-site scripting (XSS) attack that may lead to arbitrary code execution with `SYSTEM` privileges on the application server. (ZDI-CAN-19823)

CVSS3: 8.3
EPSS: Низкий
fstec логотип

BDU:2023-08150

больше 2 лет назад

Уязвимость программного обеспечения управления и конфигурирования сети Siemens SINEMA Server, позволяющая нарушителю выполнить произвольный код с привилегиями SYSTEM

CVSS3: 8.3
EPSS: Низкий

Уязвимостей на страницу

Уязвимость
CVSS
EPSS
Опубликовано
nvd логотип
CVE-2023-35796

A vulnerability has been identified in SINEMA Server V14 (All versions). The affected application improperly sanitizes certain SNMP configuration data retrieved from monitored devices. An attacker with access to a monitored device could perform a stored cross-site scripting (XSS) attack that may lead to arbitrary code execution with `SYSTEM` privileges on the application server. (ZDI-CAN-19823)

CVSS3: 8.3
0%
Низкий
больше 2 лет назад
github логотип
GHSA-8w38-353q-pxjf

A vulnerability has been identified in SINEMA Server V14 (All versions). The affected application improperly sanitizes certain SNMP configuration data retrieved from monitored devices. An attacker with access to a monitored device could perform a stored cross-site scripting (XSS) attack that may lead to arbitrary code execution with `SYSTEM` privileges on the application server. (ZDI-CAN-19823)

CVSS3: 8.3
0%
Низкий
больше 2 лет назад
fstec логотип
BDU:2023-08150

Уязвимость программного обеспечения управления и конфигурирования сети Siemens SINEMA Server, позволяющая нарушителю выполнить произвольный код с привилегиями SYSTEM

CVSS3: 8.3
0%
Низкий
больше 2 лет назад

Уязвимостей на страницу