CVE-2023-5768
A vulnerability exists in the HCI IEC 60870-5-104 that affects the RTU500 series product versions listed below. Incomplete or wrong received APDU frame layout may cause blocking on link layer. Error reason was an endless blocking when reading incoming frames on link layer with wrong length information of APDU or delayed reception of data octets. Only communication link of affected HCI IEC 60870-5-104 is blocked. If attack sequence stops the communication to the previously attacked link gets normal again.
GHSA-gv34-7cg2-7vfg
A vulnerability exists in the HCI IEC 60870-5-104 that affects the RTU500 series product versions listed below. Incomplete or wrong received APDU frame layout may cause blocking on link layer. Error reason was an endless blocking when reading incoming frames on link layer with wrong length information of APDU or delayed reception of data octets. Only communication link of affected HCI IEC 60870-5-104 is blocked. If attack sequence stops the communication to the previously attacked link gets normal again.
BDU:2024-00034
Уязвимость компонента APDU Frame Layout Handler программируемых логических контроллеров Hitachi Energy RTU500 серии CMU, позволяющая нарушителю вызвать отказ в обслуживании
Уязвимостей на страницу
Уязвимость | CVSS | EPSS | Опубликовано | |
|---|---|---|---|---|
CVE-2023-5768 A vulnerability exists in the HCI IEC 60870-5-104 that affects the RTU500 series product versions listed below. Incomplete or wrong received APDU frame layout may cause blocking on link layer. Error reason was an endless blocking when reading incoming frames on link layer with wrong length information of APDU or delayed reception of data octets. Only communication link of affected HCI IEC 60870-5-104 is blocked. If attack sequence stops the communication to the previously attacked link gets normal again. | CVSS3: 5.9 | 0% Низкий | около 2 лет назад | |
GHSA-gv34-7cg2-7vfg A vulnerability exists in the HCI IEC 60870-5-104 that affects the RTU500 series product versions listed below. Incomplete or wrong received APDU frame layout may cause blocking on link layer. Error reason was an endless blocking when reading incoming frames on link layer with wrong length information of APDU or delayed reception of data octets. Only communication link of affected HCI IEC 60870-5-104 is blocked. If attack sequence stops the communication to the previously attacked link gets normal again. | CVSS3: 5.9 | 0% Низкий | около 2 лет назад | |
BDU:2024-00034 Уязвимость компонента APDU Frame Layout Handler программируемых логических контроллеров Hitachi Energy RTU500 серии CMU, позволяющая нарушителю вызвать отказ в обслуживании | CVSS3: 5.9 | 0% Низкий | около 2 лет назад |