Количество 2
Количество 2
CVE-2023-6275
A vulnerability was found in TOTVS Fluig Platform 1.6.x/1.7.x/1.8.0/1.8.1. It has been rated as problematic. Affected by this issue is some unknown functionality of the file /mobileredir/openApp.jsp of the component mobileredir. The manipulation of the argument redirectUrl/user with the input "><script>alert(document.domain)</script> leads to cross site scripting. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. Upgrading to version 1.7.1-231128, 1.8.0-231127 and 1.8.1-231127 is able to address this issue. It is recommended to upgrade the affected component. The identifier of this vulnerability is VDB-246104.
GHSA-94vc-pmgm-jvw4
A vulnerability was found in TOTVS Fluig Platform 1.6.x/1.7.x/1.8.0/1.8.1. It has been rated as problematic. Affected by this issue is some unknown functionality of the file /mobileredir/openApp.jsp of the component mobileredir. The manipulation of the argument redirectUrl/user with the input "><script>alert(document.domain)</script> leads to cross site scripting. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-246104. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Уязвимостей на страницу
Уязвимость | CVSS | EPSS | Опубликовано | |
|---|---|---|---|---|
CVE-2023-6275 A vulnerability was found in TOTVS Fluig Platform 1.6.x/1.7.x/1.8.0/1.8.1. It has been rated as problematic. Affected by this issue is some unknown functionality of the file /mobileredir/openApp.jsp of the component mobileredir. The manipulation of the argument redirectUrl/user with the input "><script>alert(document.domain)</script> leads to cross site scripting. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. Upgrading to version 1.7.1-231128, 1.8.0-231127 and 1.8.1-231127 is able to address this issue. It is recommended to upgrade the affected component. The identifier of this vulnerability is VDB-246104. | CVSS3: 3.5 | 52% Средний | около 2 лет назад | |
GHSA-94vc-pmgm-jvw4 A vulnerability was found in TOTVS Fluig Platform 1.6.x/1.7.x/1.8.0/1.8.1. It has been rated as problematic. Affected by this issue is some unknown functionality of the file /mobileredir/openApp.jsp of the component mobileredir. The manipulation of the argument redirectUrl/user with the input "><script>alert(document.domain)</script> leads to cross site scripting. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-246104. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | CVSS3: 3.5 | 52% Средний | около 2 лет назад |
Уязвимостей на страницу