Логотип exploitDog
bind:CVE-2024-0932
Консоль
Логотип exploitDog

exploitDog

bind:CVE-2024-0932

Количество 3

Количество 3

nvd логотип

CVE-2024-0932

около 2 лет назад

A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.49_multi_TDE01. This issue affects the function setSmartPowerManagement. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-252137 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

CVSS3: 4.7
EPSS: Низкий
github логотип

GHSA-p7hc-wp5x-pvx7

около 2 лет назад

A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.49_multi_TDE01. This issue affects the function setSmartPowerManagement. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-252137 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

CVSS3: 4.7
EPSS: Низкий
fstec логотип

BDU:2024-00819

около 2 лет назад

Уязвимость функции setSmartPowerManagement микропрограммного обеспечения маршрутизаторов Tenda AC10U, позволяющая нарушителю оказать воздействие на конфиденциальность, целостность и доступность защищаемой информации

CVSS3: 4.7
EPSS: Низкий

Уязвимостей на страницу

Уязвимость
CVSS
EPSS
Опубликовано
nvd логотип
CVE-2024-0932

A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.49_multi_TDE01. This issue affects the function setSmartPowerManagement. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-252137 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

CVSS3: 4.7
0%
Низкий
около 2 лет назад
github логотип
GHSA-p7hc-wp5x-pvx7

A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.49_multi_TDE01. This issue affects the function setSmartPowerManagement. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-252137 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

CVSS3: 4.7
0%
Низкий
около 2 лет назад
fstec логотип
BDU:2024-00819

Уязвимость функции setSmartPowerManagement микропрограммного обеспечения маршрутизаторов Tenda AC10U, позволяющая нарушителю оказать воздействие на конфиденциальность, целостность и доступность защищаемой информации

CVSS3: 4.7
0%
Низкий
около 2 лет назад

Уязвимостей на страницу