Логотип exploitDog
bind:CVE-2024-2763
Консоль
Логотип exploitDog

exploitDog

bind:CVE-2024-2763

Количество 3

Количество 3

nvd логотип

CVE-2024-2763

почти 2 года назад

A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.48. Affected by this issue is the function formSetCfm of the file goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257600. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

CVSS3: 8.8
EPSS: Низкий
github логотип

GHSA-c7cm-2h42-m8x5

почти 2 года назад

A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.48. Affected by this issue is the function formSetCfm of the file goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257600. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

CVSS3: 8.8
EPSS: Низкий
fstec логотип

BDU:2024-02292

почти 2 года назад

Уязвимость функции formSetCfm (goform/setcfm) микропрограммного обеспечения маршрутизаторов Tenda AC10U, позволяющая нарушителю оказать воздействие на конфиденциальность, целостность и доступность защищаемой информации

CVSS3: 8.8
EPSS: Низкий

Уязвимостей на страницу

Уязвимость
CVSS
EPSS
Опубликовано
nvd логотип
CVE-2024-2763

A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.48. Affected by this issue is the function formSetCfm of the file goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257600. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

CVSS3: 8.8
0%
Низкий
почти 2 года назад
github логотип
GHSA-c7cm-2h42-m8x5

A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.48. Affected by this issue is the function formSetCfm of the file goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257600. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

CVSS3: 8.8
0%
Низкий
почти 2 года назад
fstec логотип
BDU:2024-02292

Уязвимость функции formSetCfm (goform/setcfm) микропрограммного обеспечения маршрутизаторов Tenda AC10U, позволяющая нарушителю оказать воздействие на конфиденциальность, целостность и доступность защищаемой информации

CVSS3: 8.8
0%
Низкий
почти 2 года назад

Уязвимостей на страницу