Количество 3
Количество 3
CVE-2024-2892
A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this vulnerability is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257935. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
GHSA-c8h5-49j5-398q
A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this vulnerability is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257935. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
BDU:2024-02659
Уязвимость функции formSetCfm (/goform/setcfm) микропрограммного обеспечения маршрутизаторов Tenda AC7, позволяющая нарушителю оказать воздействие на конфиденциальность, целостность и доступность защищаемой информации
Уязвимостей на страницу
Уязвимость | CVSS | EPSS | Опубликовано | |
|---|---|---|---|---|
CVE-2024-2892 A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this vulnerability is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257935. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | CVSS3: 8.8 | 0% Низкий | почти 2 года назад | |
GHSA-c8h5-49j5-398q A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this vulnerability is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257935. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | CVSS3: 8.8 | 0% Низкий | почти 2 года назад | |
BDU:2024-02659 Уязвимость функции formSetCfm (/goform/setcfm) микропрограммного обеспечения маршрутизаторов Tenda AC7, позволяющая нарушителю оказать воздействие на конфиденциальность, целостность и доступность защищаемой информации | CVSS3: 8.8 | 0% Низкий | почти 2 года назад |
Уязвимостей на страницу