Логотип exploitDog
bind:CVE-2024-2892
Консоль
Логотип exploitDog

exploitDog

bind:CVE-2024-2892

Количество 3

Количество 3

nvd логотип

CVE-2024-2892

почти 2 года назад

A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this vulnerability is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257935. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

CVSS3: 8.8
EPSS: Низкий
github логотип

GHSA-c8h5-49j5-398q

почти 2 года назад

A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this vulnerability is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257935. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

CVSS3: 8.8
EPSS: Низкий
fstec логотип

BDU:2024-02659

почти 2 года назад

Уязвимость функции formSetCfm (/goform/setcfm) микропрограммного обеспечения маршрутизаторов Tenda AC7, позволяющая нарушителю оказать воздействие на конфиденциальность, целостность и доступность защищаемой информации

CVSS3: 8.8
EPSS: Низкий

Уязвимостей на страницу

Уязвимость
CVSS
EPSS
Опубликовано
nvd логотип
CVE-2024-2892

A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this vulnerability is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257935. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

CVSS3: 8.8
0%
Низкий
почти 2 года назад
github логотип
GHSA-c8h5-49j5-398q

A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this vulnerability is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257935. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

CVSS3: 8.8
0%
Низкий
почти 2 года назад
fstec логотип
BDU:2024-02659

Уязвимость функции formSetCfm (/goform/setcfm) микропрограммного обеспечения маршрутизаторов Tenda AC7, позволяющая нарушителю оказать воздействие на конфиденциальность, целостность и доступность защищаемой информации

CVSS3: 8.8
0%
Низкий
почти 2 года назад

Уязвимостей на страницу