Количество 3
Количество 3
CVE-2024-2893
A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this issue is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257936. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
GHSA-7766-vp76-r5pj
A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this issue is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257936. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
BDU:2024-02663
Уязвимость функции formSetDeviceName (/goform/SetOnlineDevName) микропрограммного обеспечения маршрутизаторов Tenda AC7, позволяющая нарушителю оказать воздействие на конфиденциальность, целостность и доступность защищаемой информации
Уязвимостей на страницу
Уязвимость | CVSS | EPSS | Опубликовано | |
|---|---|---|---|---|
CVE-2024-2893 A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this issue is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257936. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | CVSS3: 8.8 | 0% Низкий | почти 2 года назад | |
GHSA-7766-vp76-r5pj A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this issue is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257936. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | CVSS3: 8.8 | 0% Низкий | почти 2 года назад | |
BDU:2024-02663 Уязвимость функции formSetDeviceName (/goform/SetOnlineDevName) микропрограммного обеспечения маршрутизаторов Tenda AC7, позволяющая нарушителю оказать воздействие на конфиденциальность, целостность и доступность защищаемой информации | CVSS3: 8.8 | 0% Низкий | почти 2 года назад |
Уязвимостей на страницу