Количество 3
Количество 3
CVE-2024-45476
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted WRL files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.
GHSA-jwwf-228q-572h
A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted WRL files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.
BDU:2024-11606
Уязвимость системы управления жизненным циклом продукции Teamcenter Visualization и программной среды имитационного моделирования систем и процессов Siemens Tecnomatix Plant Simulation, связанная с ошибками разыменования указателей, позволяющая нарушителю вызвать отказ в обслуживании
Уязвимостей на страницу
Уязвимость | CVSS | EPSS | Опубликовано | |
|---|---|---|---|---|
CVE-2024-45476 A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted WRL files. An attacker could leverage this vulnerability to crash the application causing denial of service condition. | CVSS3: 3.3 | 0% Низкий | больше 1 года назад | |
GHSA-jwwf-228q-572h A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted WRL files. An attacker could leverage this vulnerability to crash the application causing denial of service condition. | CVSS3: 3.3 | 0% Низкий | больше 1 года назад | |
BDU:2024-11606 Уязвимость системы управления жизненным циклом продукции Teamcenter Visualization и программной среды имитационного моделирования систем и процессов Siemens Tecnomatix Plant Simulation, связанная с ошибками разыменования указателей, позволяющая нарушителю вызвать отказ в обслуживании | CVSS3: 3.3 | 0% Низкий | больше 1 года назад |
Уязвимостей на страницу