Логотип exploitDog
bind:CVE-2024-47808
Консоль
Логотип exploitDog

exploitDog

bind:CVE-2024-47808

Количество 3

Количество 3

nvd логотип

CVE-2024-47808

около 1 года назад

A vulnerability has been identified in SINEC NMS (All versions < V3.0 SP1). The affected application contains a database function, that does not properly restrict the permissions of users to write to the filesystem of the host system. This could allow an authenticated medium-privileged attacker to write arbitrary content to any location in the filesystem of the host system.

CVSS3: 8.4
EPSS: Низкий
github логотип

GHSA-pjpw-9hx5-m28p

около 1 года назад

A vulnerability has been identified in SINEC NMS (All versions < V3.0 SP1). The affected application contains a database function, that does not properly restrict the permissions of users to write to the filesystem of the host system. This could allow an authenticated medium-privileged attacker to write arbitrary content to any location in the filesystem of the host system.

CVSS3: 8.4
EPSS: Низкий
fstec логотип

BDU:2024-10320

около 1 года назад

Уязвимость системы сетевого управления для мониторинга промышленными сетями Siemens SINEC NMS, связанная с неправильным присвоением разрешений для критичного ресурса, позволяющая нарушителю записывать произвольные данные в произвольное место файловой системы хоста

CVSS3: 8.4
EPSS: Низкий

Уязвимостей на страницу

Уязвимость
CVSS
EPSS
Опубликовано
nvd логотип
CVE-2024-47808

A vulnerability has been identified in SINEC NMS (All versions < V3.0 SP1). The affected application contains a database function, that does not properly restrict the permissions of users to write to the filesystem of the host system. This could allow an authenticated medium-privileged attacker to write arbitrary content to any location in the filesystem of the host system.

CVSS3: 8.4
0%
Низкий
около 1 года назад
github логотип
GHSA-pjpw-9hx5-m28p

A vulnerability has been identified in SINEC NMS (All versions < V3.0 SP1). The affected application contains a database function, that does not properly restrict the permissions of users to write to the filesystem of the host system. This could allow an authenticated medium-privileged attacker to write arbitrary content to any location in the filesystem of the host system.

CVSS3: 8.4
0%
Низкий
около 1 года назад
fstec логотип
BDU:2024-10320

Уязвимость системы сетевого управления для мониторинга промышленными сетями Siemens SINEC NMS, связанная с неправильным присвоением разрешений для критичного ресурса, позволяющая нарушителю записывать произвольные данные в произвольное место файловой системы хоста

CVSS3: 8.4
0%
Низкий
около 1 года назад

Уязвимостей на страницу