Логотип exploitDog
bind:CVE-2024-50374
Консоль
Логотип exploitDog

exploitDog

bind:CVE-2024-50374

Количество 3

Количество 3

nvd логотип

CVE-2024-50374

около 1 года назад

A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "capture_packages" operation.

CVSS3: 9.8
EPSS: Низкий
github логотип

GHSA-f4h2-jrxj-q4vg

около 1 года назад

A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "capture_packages" operation.

CVSS3: 9.8
EPSS: Низкий
fstec логотип

BDU:2024-10430

больше 1 года назад

Уязвимость функции capture_packages многофункциональных беспроводных точек доступа Advantech EKI-6333AC-2G, EKI-6333AC-2GD и EKI-6333AC-1GPO, позволяющая нарушителю выполнить произвольные команды

CVSS3: 9.8
EPSS: Низкий

Уязвимостей на страницу

Уязвимость
CVSS
EPSS
Опубликовано
nvd логотип
CVE-2024-50374

A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "capture_packages" operation.

CVSS3: 9.8
1%
Низкий
около 1 года назад
github логотип
GHSA-f4h2-jrxj-q4vg

A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "capture_packages" operation.

CVSS3: 9.8
1%
Низкий
около 1 года назад
fstec логотип
BDU:2024-10430

Уязвимость функции capture_packages многофункциональных беспроводных точек доступа Advantech EKI-6333AC-2G, EKI-6333AC-2GD и EKI-6333AC-1GPO, позволяющая нарушителю выполнить произвольные команды

CVSS3: 9.8
1%
Низкий
больше 1 года назад

Уязвимостей на страницу