Логотип exploitDog
bind:CVE-2024-50376
Консоль
Логотип exploitDog

exploitDog

bind:CVE-2024-50376

Количество 3

Количество 3

nvd логотип

CVE-2024-50376

около 1 года назад

A CWE-79 "Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited remotely leveraging a rogue Wi-Fi access point with a malicious SSID.

CVSS3: 7.3
EPSS: Низкий
github логотип

GHSA-9q6m-jvw2-h293

около 1 года назад

A CWE-79 "Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited remotely leveraging a rogue Wi-Fi access point with a malicious SSID.

CVSS3: 7.3
EPSS: Низкий
fstec логотип

BDU:2024-10429

больше 1 года назад

Уязвимость микропрограммного обеспечения многофункциональных беспроводных точек доступа Advantech EKI-6333AC-2G, EKI-6333AC-2GD и EKI-6333AC-1GPO, позволяющая нарушителю выполнить произвольные команды

CVSS3: 7.3
EPSS: Низкий

Уязвимостей на страницу

Уязвимость
CVSS
EPSS
Опубликовано
nvd логотип
CVE-2024-50376

A CWE-79 "Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited remotely leveraging a rogue Wi-Fi access point with a malicious SSID.

CVSS3: 7.3
0%
Низкий
около 1 года назад
github логотип
GHSA-9q6m-jvw2-h293

A CWE-79 "Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited remotely leveraging a rogue Wi-Fi access point with a malicious SSID.

CVSS3: 7.3
0%
Низкий
около 1 года назад
fstec логотип
BDU:2024-10429

Уязвимость микропрограммного обеспечения многофункциональных беспроводных точек доступа Advantech EKI-6333AC-2G, EKI-6333AC-2GD и EKI-6333AC-1GPO, позволяющая нарушителю выполнить произвольные команды

CVSS3: 7.3
0%
Низкий
больше 1 года назад

Уязвимостей на страницу