Количество 3
Количество 3
CVE-2024-8224
A vulnerability, which was classified as critical, has been found in Tenda G3 15.11.0.20. This issue affects the function formSetDebugCfg of the file /goform/setDebugCfg. The manipulation of the argument enable/level/module leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
GHSA-w54j-2qcv-5gf2
A vulnerability, which was classified as critical, has been found in Tenda G3 15.11.0.20. This issue affects the function formSetDebugCfg of the file /goform/setDebugCfg. The manipulation of the argument enable/level/module leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
BDU:2024-10274
Уязвимость функции formSetDebugCfg микропрограммного обеспечения беспроводной точки доступа Tenda G3, позволяющая нарушителю выполнить произвольный код
Уязвимостей на страницу
Уязвимость | CVSS | EPSS | Опубликовано | |
|---|---|---|---|---|
CVE-2024-8224 A vulnerability, which was classified as critical, has been found in Tenda G3 15.11.0.20. This issue affects the function formSetDebugCfg of the file /goform/setDebugCfg. The manipulation of the argument enable/level/module leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | CVSS3: 8.8 | 0% Низкий | больше 1 года назад | |
GHSA-w54j-2qcv-5gf2 A vulnerability, which was classified as critical, has been found in Tenda G3 15.11.0.20. This issue affects the function formSetDebugCfg of the file /goform/setDebugCfg. The manipulation of the argument enable/level/module leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | CVSS3: 8.8 | 0% Низкий | больше 1 года назад | |
BDU:2024-10274 Уязвимость функции formSetDebugCfg микропрограммного обеспечения беспроводной точки доступа Tenda G3, позволяющая нарушителю выполнить произвольный код | CVSS3: 9.8 | 0% Низкий | больше 1 года назад |
Уязвимостей на страницу