CVE-2025-4340

9 месяцев назад

A vulnerability classified as critical has been found in D-Link DIR-890L and DIR-806A1 up to 100CNb11/108B03. Affected is the function sub_175C8 of the file /htdocs/soap.cgi. The manipulation leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

CVSS3: 6.3
EPSS: Низкий
github логотип

GHSA-rh69-7g6g-53pr

9 месяцев назад

A vulnerability classified as critical has been found in D-Link DIR-890L and DIR-806A1 up to 100CNb11/108B03. Affected is the function sub_175C8 of the file /htdocs/soap.cgi. The manipulation leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

CVSS3: 6.3
EPSS: Низкий
fstec логотип

BDU:2025-05480

9 месяцев назад

Уязвимость функции sub_175C8 файла /htdocs/soap.cgi микропрограммного обеспечения маршрутизаторов D-Link DIR-890L и DIR-806A1, связанная с непринятием мер по чистке данных на управляющем уровне, позволяющая нарушителю выполнить произвольные команды

CVSS3: 6.3
EPSS: Низкий

Уязвимостей на страницу

Уязвимость
CVSS
EPSS
Опубликовано
nvd логотип
CVE-2025-4340

A vulnerability classified as critical has been found in D-Link DIR-890L and DIR-806A1 up to 100CNb11/108B03. Affected is the function sub_175C8 of the file /htdocs/soap.cgi. The manipulation leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

CVSS3: 6.3
0%
Низкий
9 месяцев назад
github логотип
GHSA-rh69-7g6g-53pr

A vulnerability classified as critical has been found in D-Link DIR-890L and DIR-806A1 up to 100CNb11/108B03. Affected is the function sub_175C8 of the file /htdocs/soap.cgi. The manipulation leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

CVSS3: 6.3
0%
Низкий
9 месяцев назад
fstec логотип
BDU:2025-05480

Уязвимость функции sub_175C8 файла /htdocs/soap.cgi микропрограммного обеспечения маршрутизаторов D-Link DIR-890L и DIR-806A1, связанная с непринятием мер по чистке данных на управляющем уровне, позволяющая нарушителю выполнить произвольные команды

CVSS3: 6.3
0%
Низкий
9 месяцев назад