Логотип exploitDog
bind:CVE-2022-33174
Консоль
Логотип exploitDog

exploitDog

bind:CVE-2022-33174

Количество 2

Количество 2

nvd логотип

CVE-2022-33174

больше 3 лет назад

Power Distribution Units running on Powertek firmware (multiple brands) before 3.30.30 allows remote authorization bypass in the web interface. To exploit the vulnerability, an attacker must send an HTTP packet to the data retrieval interface (/cgi/get_param.cgi) with the tmpToken cookie set to an empty string followed by a semicolon. This bypasses an active session authorization check. This can be then used to fetch the values of protected sys.passwd and sys.su.name fields that contain the username and password in cleartext.

CVSS3: 9.8
EPSS: Высокий
github логотип

GHSA-583h-x99p-fmcc

больше 3 лет назад

Power Distribution Units running on Powertek firmware (multiple brands) before 3.30.30 allows remote authorization bypass in the web interface. To exploit the vulnerability, an attacker must send an HTTP packet to the data retrieval interface (/cgi/get_param.cgi) with the tmpToken cookie set to an empty string followed by a semicolon. This bypasses an active session authorization check. This can be then used to fetch the values of protected sys.passwd and sys.su.name fields that contain the username and password in cleartext.

CVSS3: 7.5
EPSS: Высокий

Уязвимостей на страницу

Уязвимость
CVSS
EPSS
Опубликовано
nvd логотип
CVE-2022-33174

Power Distribution Units running on Powertek firmware (multiple brands) before 3.30.30 allows remote authorization bypass in the web interface. To exploit the vulnerability, an attacker must send an HTTP packet to the data retrieval interface (/cgi/get_param.cgi) with the tmpToken cookie set to an empty string followed by a semicolon. This bypasses an active session authorization check. This can be then used to fetch the values of protected sys.passwd and sys.su.name fields that contain the username and password in cleartext.

CVSS3: 9.8
82%
Высокий
больше 3 лет назад
github логотип
GHSA-583h-x99p-fmcc

Power Distribution Units running on Powertek firmware (multiple brands) before 3.30.30 allows remote authorization bypass in the web interface. To exploit the vulnerability, an attacker must send an HTTP packet to the data retrieval interface (/cgi/get_param.cgi) with the tmpToken cookie set to an empty string followed by a semicolon. This bypasses an active session authorization check. This can be then used to fetch the values of protected sys.passwd and sys.su.name fields that contain the username and password in cleartext.

CVSS3: 7.5
82%
Высокий
больше 3 лет назад

Уязвимостей на страницу